PRODUCT SKU : IC200PBI001

PRODUCT TYPE : Profibus Network Interface Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax IC200PBI001 Profibus Network Interface Module provides seamless integration of VersaMax systems into Profibus networks. Designed for efficient communication, it supports multiple I/O modules and a wide range of network addresses, ensuring reliable data exchange in industrial automation environments.

Technical Specifications

  • Model / Part Number IC200PBI001

  • Manufacturer GE Fanuc Emerson

  • Product Line VersaMax

  • Product Type Profibus Network Interface Module

  • Weight 0.31 lbs (0.14 kg)

  • Current Consumption 250 mA

  • Supported I/O Modules Up to 64 modules

  • Network Address Range 1–125

  • Network Data Rate 9.6 Kbps to 12 Mbps

  • User Diagnostics Data 5 bytes

  • Connector Type 9-pin D-sub

Application Scenarios

  • Integration of VersaMax PLCs into Profibus-based automation networks

  • Multi-module communication setups requiring stable and scalable connectivity

  • Industrial systems needing compact and efficient Profibus interface solutions

FAQ

Q: How many I/O modules can the IC200PBI001 support?  A: It supports up to 64 I/O modules.

Q: What is the available network address range?  A: The module allows configuration from address 1 to 125.

Q: What connector type is used?  A: A 9-pin D-sub connector is provided for Profibus communication.

Q: What data rates are supported?  A: The module supports speeds from 9.6 Kbps up to 12 Mbps.

Comparison with Similar Models

  • IC200PBI001: Profibus interface, 64 I/O modules, 9-pin D-sub connector

  • IC200DBI001-DA: DeviceNet interface, supports 64 nodes and 8 modules

  • IC200CMM020: Serial communications module with RS-232 and RS-485 ports

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more