Honeywell TK-HAO081 HC900 Analog Output ModuleHoneywell TK-HAO081 HC900 Analog Output ModuleHoneywell TK-HAO081 HC900 Analog Output Module
Honeywell TK-HAO081 HC900 Analog Output Module
Honeywell TK-HAO081 HC900 Analog Output Module
Honeywell TK-HAO081 HC900 Analog Output Module

Honeywell TK-HAO081 HC900 Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : TK-HAO081

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell TK-HAO081 is an 8-channel analog output module designed for process control and automation within the Honeywell HC900 control platform. It provides precise high-resolution signal generation to control field devices such as control valves, variable frequency drives, and positioners.

Channel Flexibility and Signal Conversion

The module features eight independent channels configurable for both voltage (0-10 V, 0-5 V) and current (0-20 mA, 4-20 mA) outputs. Built with 16-bit resolution, each output point can be individually programmed to meet precise loop requirements with a fast signal update time of less than 1 ms.

System Protection and Onboard Diagnostics

Electrical integrity is maintained through 500 VDC galvanic isolation, protecting backplane logic from field-side interference. Built-in diagnostic capabilities continuously monitor output loop health to simplify fault isolation and maintenance troubleshooting within HC900 cabinet racks.

Parameter Specification
Model TK-HAO081
Brand Honeywell
Series HC900
Product Type Analog Output Module
Output Channels 8
Output Signal Types Voltage (0-10 V, 0-5 V), Current (0-20 mA, 4-20 mA)
Resolution 16 bits
Output Range Programmable per channel
Update Time <1 ms
Isolation 500 VDC
Dimensions 112 mm x 120 mm x 38 mm
Weight 0.4 kg

Frequently Asked Questions

Q: Can channels on the TK-HAO081 be configured for different output types simultaneously?

A: Yes, each of the 8 output channels allows individual configuration for voltage or current signals according to application requirements.

Q: Which Honeywell control system is compatible with the TK-HAO081 module?

A: The module is part of the modular Honeywell HC900 control system architecture.

Q: What level of isolation does the TK-HAO081 provide?

A: The module features 500 VDC galvanic isolation to safeguard controller circuitry from field noise and ground loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more