Skip to content

What are you looking for?


You may also like

Honeywell TC-IDD321 Digital Input ModuleHoneywell TC-IDD321 Digital Input ModuleHoneywell TC-IDD321 Digital Input Module
Honeywell TC-IDD321 Digital Input Module
Honeywell TC-IDD321 Digital Input Module
Honeywell TC-IDD321 Digital Input Module

Honeywell TC-IDD321 Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : TC-IDD321

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell TC-IDD321 is a 32-channel discrete digital input module engineered for Honeywell Experion LS control systems. Operating at a nominal input voltage of 24 VDC, it conditions high-density binary signals from field switches, proximity sensors, and contact points across two isolated 16-point groups.

Input Electrical Limits and IEC Compliance

The module complies with IEC Type 1+ input signal standards to ensure broad field instrument compatibility. It establishes a minimum on-state current of 2 mA to confirm active signal states, while maintaining an off-state threshold capped at a maximum 5 V and 1.5 mA leakage current to prevent false switching.

Circuit Isolation and Wiring Interfacing

Built to safeguard system electronics from electrical noise and field transients, the TC-IDD321 features galvanic isolation tested at 1500 VDC for 1 second both between input channels and between field-side user circuits and the system backplane. Field wiring connects through a 36-position terminal block (model TC-TBNH), and total power dissipation is rated at a maximum of 6.1 W.

Parameter Specification
Model TC-IDD321
Brand Honeywell
System Experion LS
Product Type Digital Input Module
Number of Inputs 32 (16 points per common)
Nominal Input Voltage 24 VDC
On-State Current (Minimum) 2 mA
Off-State Voltage (Maximum) 5 V
Off-State Current (Maximum) 1.5 mA
Input Standard Compatibility IEC Type 1+
Isolation Voltage (Channel to Channel) 1500 VDC for 1 s
Isolation Voltage (User to System) 1500 VDC for 1 s
Power Dissipation 6.1 W max
Connection Terminal Blocks TC-TBNH (36-position terminal block)
Shipping Weight 2 kg

Frequently Asked Questions

Q: How are the 32 input channels on the TC-IDD321 grouped?

A: The 32 digital input channels are arranged into two groups of 16 points per common terminal.

Q: What terminal block is required for field wiring on the TC-IDD321?

A: Field wiring connects via the TC-TBNH 36-position terminal block.

Q: What level of electrical isolation does this module provide?

A: The module provides 1500 VDC isolation for 1 second across both channel-to-channel and user-to-system circuit boundaries.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more