The Honeywell TC-IAH161 is a 16-channel high-level analog input module designed for industrial process control and data acquisition systems. It processes multi-range voltage and current signals with 16-bit resolution, providing reliable signal conversion and isolation across process measurement loops.

Input Ranges and Signal Processing

The module supports multiple configurable input ranges, including voltage spans of +/-10.25 volts, 0 to 10.25 volts, and 0 to 5.125 volts, alongside current inputs from 0 to 20.5 mA utilizing an internal 250 ohm resistor. Input impedance is greater than 1.0 megohm for voltage inputs and nominally 249 ohms for current loops. A channel bandwidth of 20 Hz (-3 dB) and a module publish rate of 250 msec ensure stable, continuous data sampling.

Electrical Protection and Interfacing

Electrical isolation between user circuits and system logic is 100% factory tested at 2550 VDC for 1 second. The unit features built-in RFI immunity limiting signal error to less than 2.0% of the range at 10 V/m across 27 to 1000 MHz. Maximum power dissipation is rated at 4.1 W, and field wiring connects through a 36-position terminal block model TC-TBCH.

Parameter Specification
Model TC-IAH161
Brand Honeywell
Product Type High-Level Analog Input Module
Number of Points 16 channels
Input Voltage Range +/-10.25 V, 0 to 10.25 V, 0 to 5.125 V
Input Current Range 0 to 20.5 mA (internal 250 ohm resistor)
Voltage Resolution 16 bits across each range
Module Publish Rate 250 msec
Input Impedance (Voltage) >1.0 megohm
Input Impedance (Current) 249 ohms nominal
Channel Bandwidth 20 Hz (-3 dB)
Isolation Voltage (User to System) 2550 VDC for 1 s
Power Dissipation 4.1 W max
Connection Terminal Blocks TC-TBCH (36-position terminal block)
Shipping Weight 1.5 kg

Frequently Asked Questions

Q: What input signal ranges does the TC-IAH161 module support?

A: The module supports voltage ranges of +/-10.25 V, 0 to 10.25 V, and 0 to 5.125 V, as well as current inputs from 0 to 20.5 mA.

Q: What terminal block is required for field wiring connections?

A: Field connections interface via the TC-TBCH 36-position terminal block.

Q: What is the isolation voltage rating for this module?

A: The user-to-system isolation voltage is factory tested at 2550 VDC for 1 second.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more