Skip to content

What are you looking for?


You may also like

Honeywell TC-IAH161 High Level Analog Input ModuleHoneywell TC-IAH161 High Level Analog Input ModuleHoneywell TC-IAH161 High Level Analog Input Module
Honeywell TC-IAH161 High Level Analog Input Module
Honeywell TC-IAH161 High Level Analog Input Module
Honeywell TC-IAH161 High Level Analog Input Module

Honeywell TC-IAH161 High Level Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : TC-IAH16I

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-resolution analog signal acquisition in Honeywell Experion PKS platforms, the Honeywell TC-IAH161 (TC-IAH161 High Level Analog Input Module) provides direct physical/electrical execution. It digitizes signals across 16 channels, supporting voltage ranges up to +/- 10.25 VDC and current inputs from 0 to 20.5 mA using internal 249 ohm precision resistors. The module converts field transmitter values into 16-bit digital variables for cyclic backplane transmission.

Hardware Specifications

Parameter Specification
Model TC-IAH161
Brand Honeywell
Origin USA
Weight 1.5 kg
Dimensions Standard Experion Chassis Form Factor
Operating Temp -20 to +70 deg C
Power Consumption 4.1 W max
Product Type Analog Input Modules
Channel Count 16 channels
Input Voltage Ranges +/- 10.25 VDC, 0 to 10.25 VDC, 0 to 5.125 VDC
Input Current Range 0 to 20.5 mA (internal 249 ohm resistor)
Resolution 16 bits across selected range
Module Publish Rate 250 msec
Input Impedance Greater than 1.0 megohm (Voltage), 249 ohms nominal (Current)
Channel Bandwidth 20 Hz (-3dB)
System Isolation 2550 VDC tested for 1 s (User to system)
Terminal Block Interface TC-TBCH 36-position terminal block

Process Control & Field Signal Conditioning

The TC-IAH161 incorporates channel-to-channel isolation and input filtering networks to eliminate high-frequency field noise. When integrated with 4-20 mA HART loop protocol transmitters and high-density DCS racks, the internal 249 ohm current sense resistors convert field loops into clean differential voltage signals. The 20 Hz input bandwidth and active filter circuits suppress common-mode voltage spikes and cross-talk, protecting internal ADC electronics while maintaining continuous signal updates to the controller backplane every 250 msec.

Frequently Asked Questions

Q: How are current signals converted to voltage values on the TC-IAH161?

A: Current loop inputs utilize internal 249 ohm nominal sense resistors onboard the module to drop 0 to 20.5 mA signals into proportional voltage inputs for the 16-bit analog-to-digital converter.

Q: What is the dielectric isolation rating between the field terminals and the system logic backplane?

A: The user-to-system electrical isolation barrier is 100% factory tested at 2550 VDC for 1 second, preventing high-voltage field transients from damaging backplane control electronics.

Field Installation Guidelines

  • Chassis Insertion: Align the module card edges with the designated slot guide rails in the Experion rack and press firmly until the rear connector fully seats into the backplane.
  • Terminal Wiring: Secure field conductors to the TC-TBCH 36-position terminal block. Tighten terminal screws to standard torque specs to avoid high-resistance terminations.
  • Shield Grounding: Ground instrument cable shields at the single point earth ground bar within the enclosure to minimize electromagnetic interference and ground loop paths.
  • Signal Separation: Maintain physical separation between low-level analog input wiring and high-voltage AC power lines within cabinet wire ducts to prevent noise coupling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.