Overview

The 8C-PAINAI is an industrial-grade analog input/output module engineered for precise multi-signal acquisition. It supports voltage, current, and thermocouple inputs, delivering high-resolution 16-bit measurements with rapid response times. Designed for harsh process control environments, it ensures reliable operation and robust system integration within Honeywell C-Series DCS and SIS platforms.

Technical Specifications

  • Model: 8C-PAINAI

  • Manufacturer: Honeywell

  • Input Channels: 8 isolated analog channels

  • Supported Signals: Voltage, current, thermocouples (J, K, T, E types)

  • Measurement Resolution: 16-bit high-accuracy conversion

  • Accuracy: ±0.1% of full scale

  • Input Ranges: 0–10 V, 0–20 mA, thermocouple inputs

  • Response Time: <10 ms for fast process updates

  • Isolation: Channel-to-channel isolation for noise immunity

  • Operating Temperature: -20°C to +70°C

  • Storage Temperature: -40°C to +85°C

  • Power Supply: 24 V DC

  • Dimensions: 157 × 106 × 35 mm

  • Protection: Built-in surge and EMI protection

Features

  • High-precision acquisition for voltage, current, and thermocouple signals

  • Fast sub-10 ms response time suitable for real-time control

  • Robust isolation to minimize interference and enhance reliability

  • Industrial durability for chemical plants, refineries, power stations, and manufacturing sites

  • Flexible integration with Honeywell C-Series DCS and SIS systems

Applications

  • Multi-signal data acquisition in process control and safety systems

  • Integration into C-Series Distributed Control Systems (DCS) and Safety Instrumented Systems (SIS)

  • Real-time monitoring in environments with high electrical noise or harsh conditions

FAQ

Q: What thermocouple types are supported?
A: The 8C-PAINAI supports J, K, T, and E thermocouples.

Q: Can the module handle current and voltage inputs simultaneously?
A: Yes, it accepts both voltage and current analog inputs across its 8 isolated channels.

Q: How does it compare with 8C-PAINA1?
A: The 8C-PAINAI offers enhanced channel isolation and EMI protection for more robust multi-signal acquisition, while 8C-PAINA1 focuses on standard analog input performance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more