In stock - Ready to ship

PRODUCT SKU : MC-GOAX02

PRODUCT TYPE : Analog Output Field Termination Assemblies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell MC-GOAX02 is an 8-channel analog output Field Termination Assembly (FTA) designed to provide galvanically isolated 4-20 mA output signals for controlling galvanically isolated (GI) field devices. This CE-compliant, conformally coated assembly uses compression terminals and supports loads with resistance below 750 ohms. Redundant operation is not supported.

Analog Output Function

The MC-GOAX02 provides eight analog output channels, each intended to deliver a 4-20 mA control signal to compatible field devices. Galvanic isolation separates the output signal circuits electrically, helping prevent unwanted current paths between connected circuits.

The 4-20 mA interface is used for continuous control signals, such as actuator positioning and other analog field commands. The specified load resistance limit is below 750 ohms and must be considered when selecting connected devices and field wiring.

Electrical Characteristics

The assembly supports 4-20 mA analog output signals with galvanic isolation for GI field device applications. The load resistance requirement is less than 750 ohms, defining the permitted external circuit load for the output signal.

The MC-GOAX02 is a field termination assembly rather than a standalone analog output controller. Its operation depends on the compatible Honeywell analog output hardware and the associated system configuration.

Terminals and Physical Configuration

The MC-GOAX02 uses compression terminals for field wiring connections. Its Size B configuration has a specified dimension of 307 mm (12.1 inches).

The assembly is CE-compliant and conformally coated. The protective coating is intended to resist the corrosive effects of humidity and most chemical gases. This coating characteristic should not be interpreted as a waterproof or unrestricted chemical exposure rating.

Redundancy Limitations

Redundant operation is explicitly not supported for the MC-GOAX02. System designs requiring redundant analog output paths should use an alternative FTA configuration with documented redundancy support rather than assuming this assembly can operate in a redundant arrangement.

Technical Specifications

Parameter Specification
Model MC-GOAX02
Brand Honeywell
Product Type Analog Output Field Termination Assembly (FTA)
Output Channels 8
Output Signal 4-20 mA
Output Isolation Galvanically Isolated
Field Device Type GI Field Devices
Maximum Load Resistance Less than 750 ohms
Terminal Type Compression
Redundancy Support No
CE Compliance CE-compliant
Conformal Coating Yes
Assembly Size Size B
Dimension 307 mm (12.1 inches)
Shipping Weight 2.0 kg

Frequently Asked Questions

Q: How many analog output channels does the Honeywell MC-GOAX02 provide?

A: The MC-GOAX02 provides eight analog output channels, with galvanically isolated 4-20 mA signals for compatible GI field devices.

Q: What is the maximum supported load resistance?

A: The specified load resistance must be less than 750 ohms. The connected field device and wiring resistance should be considered when checking the total output load.

Q: Does the MC-GOAX02 support redundant operation?

A: No. Redundancy is not supported for this FTA. Applications requiring redundant analog output arrangements need a separately verified compatible assembly.

Q: Is the MC-GOAX02 conformally coated?

A: Yes. It is a CE-compliant, conformally coated assembly. The coating provides protection against humidity and most chemical gases but does not establish a waterproof rating.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more