Skip to content

What are you looking for?


You may also like

Honeywell K4LCN4 51305099-100 LCN Processor Interface BoardHoneywell K4LCN4 51305099-100 LCN Processor Interface BoardHoneywell K4LCN4 51305099-100 LCN Processor Interface Board
Honeywell K4LCN4 51305099-100 LCN Processor Interface Board
Honeywell K4LCN4 51305099-100 LCN Processor Interface Board
Honeywell K4LCN4 51305099-100 LCN Processor Interface Board

Honeywell K4LCN4 51305099-100 LCN Processor Interface Board


Only 10 left - Selling fast

PRODUCT SKU : 51305099-100

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51305099-100, also cataloged as the 51305099 (K4LCN4) LCN Processor Interface Board, operates as a dedicated hardware component for high-speed local control network processing and system bus management within Honeywell TDC 3000 Local Control Network (LCN) architectures.

Hardware Specifications

Parameter Specification
Model 51305099-100 (K4LCN4)
Brand Honeywell
Base Model 51305099
Product Type LCN Processor Interface Board
Origin USA
Weight 0.90 kg
Dimensions Standard LCN card file slot form factor
Operating Temp 0 deg C to +60 deg C
Power Consumption Powered via backplane bus (+5 VDC / +12 VDC)
System Architecture Honeywell TDC 3000 / LCN Network Nodes
Revision / Marking Rev B / B7260

Channel-to-Channel Isolation and Bus Signal Integrity

The 51305099-100 K4LCN4 board executes real-time token-passing protocol communications across redundant TDC 3000 Local Control Network coaxial cable drops. Designed to interface directly with distributed process node controllers managing 4-20 mA HART loop protocol I/O and FOUNDATION Fieldbus sub-networks, the module utilizes transformer-isolated transceiver logic. This channel isolation structure eliminates ground loop currents between interconnected control racks, suppresses common-mode noise, and prevents external line transients from corrupting internal backplane data transfers.

Frequently Asked Questions

Q: Is the 51305099-100 board backwards compatible with earlier K4LCN card file revisions?

A: Yes, the K4LCN4 variant maintains backward slot compatibility across standard TDC 3000 LCN node card files while providing enhanced board-level timing stability.

Q: Can this processor interface board be replaced online while the LCN node is powered?

A: No, online removal or insertion without executing a controlled node failover or powering down the target slot can disrupt token passing across the active LCN bus and interrupt node communications.

Field Installation Guidelines

  • ESD Precautions: Wear a grounded wrist strap connected to the cabinet frame before handling the board to protect static-sensitive CMOS logic components.
  • Mechanical Alignment: Slide the board smoothly along the chassis card slot guide rails until the rear edge connectors interface with the backplane plane.
  • Ejector Locking: Seat the board by pressing both upper and lower faceplate ejector levers flush until they latch firmly in place.
  • Cable Strain Relief: Ensure BNC coaxial cable connections and ribbon interconnects are secured and routed through cable management channels to prevent mechanical tension on the faceplate connectors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more