Honeywell 8C-TAIMA1 Analog Input Module 16-Channel Temperature SensorHoneywell 8C-TAIMA1 Analog Input Module 16-Channel Temperature SensorHoneywell 8C-TAIMA1 Analog Input Module 16-Channel Temperature Sensor
Honeywell 8C-TAIMA1 Analog Input Module 16-Channel Temperature Sensor
Honeywell 8C-TAIMA1 Analog Input Module 16-Channel Temperature Sensor
Honeywell 8C-TAIMA1 Analog Input Module 16-Channel Temperature Sensor

Honeywell 8C-TAIMA1 Analog Input Module 16-Channel Temperature Sensor


Only 10 left - Selling fast

PRODUCT SKU : 8C-TAIMA1 51307171-175

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 8C-TAIMA1 is a precision analog input module designed for accurate temperature measurement using thermocouples and RTDs. It delivers reliable signal acquisition with 16 fully isolated input channels, ideal for integration with Honeywell Experion PKS C300 controllers.

Features

  • High Channel Density: 16 isolated inputs allow monitoring multiple temperature points simultaneously.

  • Versatile Input Support: Compatible with thermocouples (types J, K, T, E) and RTDs.

  • Precision Measurement: Low gain error with superior CMRR and NMRR ensures accurate data capture.

  • Robust Isolation: Channel-to-channel and channel-to-shield isolation for interference-free operation.

  • Cold Junction Compensation: Maintains thermocouple measurement accuracy under varying ambient conditions.

  • Open TC Detection: Ensures fault detection for sensor integrity.

  • Industrial Protection: Surge protection compliant with EN 61000-4-5.

  • Coated Design: Enhanced resistance to industrial contaminants for long-term durability.

Technical Specifications

  • Model Number: 8C-TAIMA1

  • IOTA Module: Non-redundant, coated, 9” form factor

  • Input Type: Thermocouple and RTD

  • Voltage Rating: 24 VDC

  • Module Current Rating: 120 mA

  • Input Channels: 16 fully isolated (channel-to-channel, channel-to-IOL, channel-to-power supply common)

  • Input Scan Rate: 1 second fixed (up to 16 channels/sec maximum)

  • Channel Bandwidth: 0–4.7 Hz (-3 dB)

  • Nominal Input Range (TC): -20 to +100 mV

  • Max Continuous Input (TC): ±10 V

  • Max Continuous Input (RTD): -1 to +2 V @ 100 mA

  • Gain Error: 0.05% FS max

  • Temperature Stability: ±20 ppm/°C (TC & RTD)

  • Long-Term Drift: 500 ppm

  • Input Impedance: 1 MΩ DC (TC)

  • Isolation Voltage: ±250 VDC/VAC RMS (channel-to-shield), ±33 VDC/VAC RMS (channel-to-channel)

  • CMRR: ≥120 dB at 50/60 Hz

  • NMRR: 260 dB at 50/60 Hz

  • Line Frequency Integration: Fixed 50 Hz or 60 Hz

  • RTD Excitation Current: 1 mA

  • Cold Junction Compensation: -20 to +60°C (±0.5°C typical)

  • Open TC Detection: ≥1500 Ω guaranteed trip

  • RTD Max Lead Resistance: 15 Ω

  • Surge Protection (Sensor Terminals): EN61000-4-5, 1 kV line-to-line, 2 kV line-to-ground

  • Surge Protection (Power/Serial Link): EN61000-4-5, 1 kV line-to-line, 2 kV line-to-ground

Applications

Designed for precise temperature monitoring in chemical, power, and manufacturing plants. Integrates seamlessly with Experion PKS C300 controllers for industrial process automation.

FAQ

Q: Can this module handle both thermocouples and RTDs simultaneously?
A: Yes, each input channel can be configured independently for either thermocouple or RTD signals.

Q: How does the module protect against electrical noise and surges?
A: Full channel isolation, high CMRR/NMRR, and EN61000-4-5 compliant surge protection ensure accurate readings and system reliability.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more