Skip to content

What are you looking for?


You may also like

HONEYWELL 51305482-202 Experion System CableHONEYWELL 51305482-202 Experion System CableHONEYWELL 51305482-202 Experion System Cable
HONEYWELL 51305482-202 Experion System Cable
HONEYWELL 51305482-202 Experion System Cable
HONEYWELL 51305482-202 Experion System Cable

HONEYWELL 51305482-202 Experion System Cable


Only 10 left - Selling fast

PRODUCT SKU : 51305482-202

PRODUCT TYPE : I/O Module Cable Assemblies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The HONEYWELL 51305482-202, also cataloged as the 51305482-202 Shielded Communication Cable, operates as a dedicated hardware component for analog and digital signal transmission within Honeywell Experion PKS control networks. Configured with factory-terminated connectors and dual-layer shielding, it provides direct physical execution between system control modules and field I/O interfaces.

Hardware Specifications

Parameter Specification
Model 51305482-202
Brand Honeywell
Dimensions Standard 3 meters
Operating Temp -20 to +80 deg C
Power Consumption Passive Component (0 W)
Cable Type Shielded Communication Cable
Connector Type Honeywell-Specific Factory-Terminated Connectors
Voltage Rating 300 V
Insulation Material Flame-Retardant PVC
Shielding Braided and Foil Shielding (EMI Protection)
System Compatibility Honeywell Experion PKS and Related Modules

Channel-to-Channel Isolation & DCS Connectivity

The 51305482-202 cable maintains high signal integrity by routing differential communication lines through continuous foil and braided shielding layers. Integrated channel-to-channel isolation within the interconnecting Honeywell I/O modules decouples ground potential shifts and high-frequency noise spikes present across industrial control panels. This shielded cabling architecture prevents signal corruption during real-time data transfers, sustaining deterministic communication loops alongside process instrumentation operating via the 4-20 mA HART loop protocol.

Frequently Asked Questions

Q: How does the cable shielding interface with the grounding structure of the Experion rack?

A: The integrated braid and foil shields bond directly to the metallic shell of the factory-terminated connectors, establishing grounding via the module chassis interface upon connection.

Q: Can the 51305482-202 cable carry both analog and digital signaling vectors?

A: Yes, the cable construction is specified to route low-voltage analog process signals and high-speed digital communication signals between supported Honeywell modules.

Field Installation Guidelines

  1. Inspect the factory-terminated connector contacts and outer strain-relief boots for mechanical damage prior to installation.
  2. Route the cable through dedicated low-voltage wireways, maintaining physical separation from AC power leads and motor drive cables.
  3. Observe standard minimum bend radius restrictions to avoid deforming the outer PVC jacket or disrupting the internal foil shield layer.
  4. Insert the Honeywell-specific connector firmly into the module receptacle until the retention clip engages fully to lock the cable in place.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more
Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

In industrial automation, connecting physical hardware with high-level software remains a primary operational challenge. Factories utilize programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and smart sensors from diverse vendors. These devices often speak different proprietary protocols. Open Platform Communications (OPC) servers solve this interoperability challenge by standardizing how data flows across factory networks.

Read more
Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Modern factory automation relies heavily on fiber optic cables for high-speed industrial data transmission. Fiber optic cables transmit light pulses instead of electrical signals, eliminating electromagnetic interference (EMI) risks completely. Each optical strand consists of a high-purity glass core surrounded by a protective cladding layer. The difference in refractive index between core and cladding enables total internal reflection. Protective resin buffers, Kevlar strength members, and rugged outer jackets safeguard delicate glass cores in harsh environments. Consequently, automation engineers prefer fiber backbones for reliable noise-free communication in industrial control systems.

Read more