Skip to content

What are you looking for?


You may also like

Honeywell 51305072-200 TDC 3000 CLCN-A LCN Interface CardHoneywell 51305072-200 TDC 3000 CLCN-A LCN Interface CardHoneywell 51305072-200 TDC 3000 CLCN-A LCN Interface Card
Honeywell 51305072-200 TDC 3000 CLCN-A LCN Interface Card
Honeywell 51305072-200 TDC 3000 CLCN-A LCN Interface Card
Honeywell 51305072-200 TDC 3000 CLCN-A LCN Interface Card

Honeywell 51305072-200 TDC 3000 CLCN-A LCN Interface Card


Only 10 left - Selling fast

PRODUCT SKU : 51305072-200

PRODUCT TYPE : Interface Card

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51305072-200 acts as a high-performance CLCN-A Local Control Network (LCN) interface card within the Honeywell TDC 3000 distributed control architecture. This module establishes a deterministic, high-speed communication path between individual system nodes and the primary LCN backbone over ControlNet protocols. We deliver this hardware in 100% brand new, original factory condition to ensure seamless network integration, eliminate transmission drops, and preserve system integrity.

Technical Specifications

Parameter Specification
Card Type CLCN-A LCN Interface Card
System Compatibility Honeywell TDC 3000
Communication Protocol ControlNet
Data Transmission Speed 5 Mbps
Memory Capacity 50 MB
Cable Interface & Connector LCN "A" coaxial cable with BNC tees
Power Supply Requirements 24V DC ±10%
Power Consumption 15W
Mounting Configuration Dual-node chassis
Ingress Protection Rating IP20
Operating Temperature -20°C to +55°C
Storage Temperature -40°C to +85°C
Physical Dimensions 180 x 70 x 40 mm
Net Weight 180g

Engineering Advantages

  • Prevents Total Network Disruption During Maintenance: The integrated BNC tee connector design allows instrumentation engineers to disconnect individual nodes for servicing without breaking the coaxial loop or dropping communication to adjacent live nodes.

  • Maintains Throughput in High-Traffic Environments: The onboard 50MB memory buffer processes deterministic ControlNet traffic at a sustained 5 Mbps, preventing packet loss during heavy plant upset conditions.

  • Lowers Panel Thermal Load: The highly optimized circuitry draws only 15W of 24V DC power, minimizing heat dissipation inside enclosed dual-node chassis and extending the lifespan of neighboring components.

  • Fits Compact System Rack Enclosures: The streamlined 180 x 70 x 40 mm footprint easily slots into standard dual-node chassis alignments, resolving the challenge of upgrading legacy systems within constrained physical layouts.

FAQs

  • Can I disconnect this card from the network while the rest of the DCS system operates?

    Yes. The 51305072-200 utilizes specialized BNC tees. This feature allows you to isolate and remove the specific node for replacement or diagnostics without breaking the LCN "A" coaxial ring continuity.

  • Does this product arrive in surplus or re-certified condition?

    No. We sell this product strictly as a 100% brand new, authentic factory piece. It includes all original packaging and seals from the manufacturer.

  • What are the grounding requirements during the installation of this interface card?

    You must slide the card firmly into the dual-node chassis slots until the integrated grounding clips fully engage the metal rack frame. Always wear an ESD wrist strap during this procedure to protect the 50MB internal memory and processing chips from static damage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more