Skip to content

What are you looking for?


You may also like

Honeywell 51304544-100 TDC 3000 KLCN Coax Assembly Communication ModuleHoneywell 51304544-100 TDC 3000 KLCN Coax Assembly Communication ModuleHoneywell 51304544-100 TDC 3000 KLCN Coax Assembly Communication Module
Honeywell 51304544-100 TDC 3000 KLCN Coax Assembly Communication Module
Honeywell 51304544-100 TDC 3000 KLCN Coax Assembly Communication Module
Honeywell 51304544-100 TDC 3000 KLCN Coax Assembly Communication Module

Honeywell 51304544-100 TDC 3000 KLCN Coax Assembly Communication Module


Only 10 left - Selling fast

PRODUCT SKU : 51304544-100

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51304544-100 serves as a specialized KLCN Coax Assembly Communication Module within the Honeywell TDC 3000 Distributed Control System (DCS). This module facilitates the high-speed physical layer connection between Local Control Network (LCN) nodes and the coaxial cable backbone. It acts as the critical hardware interface for Operator Interface Terminals (OIT) and HMI stations, ensuring real-time data flow between the processing hardware and the operator's display. We supply this unit as 100% Brand New and Original, providing the signal integrity required to eliminate network jitter and communication dropouts.

Technical Specifications

The 51304544-100 utilizes precision-matched impedance circuitry to maintain LCN network standards across the coaxial medium.

Feature Specification
Manufacturer Honeywell
Part Number 51304544-100
Product Type KLCN Coax Assembly / Communication Module
System Compatibility Honeywell TDC 3000 / LCN Systems
Category HMI / MMI / OIT Boards
Weight 0.31 lbs (0.14 kg)
Mounting OIT Chassis / Module Rack
Condition 100% Factory New

Engineering Advantages

  • Optimized Impedance Matching: The 51304544-100 features high-tolerance passive components that strictly match the 75-ohm coaxial requirements of the LCN. This prevents signal reflections (standing waves) that typically cause intermittent node failures in older, degraded assemblies.

  • Low-Mass RF Shielding: Weighing only 0.31 lbs, this module incorporates a compact footprint with integrated electromagnetic shielding. This design rejects high-frequency interference from nearby industrial equipment, ensuring clean data packet transmission in electronically noisy control rooms.

  • Enhanced Signal Propagation: The assembly utilizes high-conductivity gold and silver plating on critical contact points. This metallurgy minimizes insertion loss and prevents the oxidation-driven signal attenuation common in refurbished hardware used in humid or chemical-heavy environments.

  • Direct Backplane Integration: The card slides into standard OIT slots with high mechanical precision. This ensures the coaxial connectors align perfectly with the external cabling, reducing mechanical stress on the PCB and preventing cracked solder joints during heavy-vibration plant operations.

FAQs

  • Does the 51304544-100 require software drivers?

    The module functions as a physical layer communication interface. While the OIT requires the correct LCN node software configuration, the hardware itself operates as a transparent signal converter. Once seated and connected to the coaxial trunk, the LCN controller detects the node presence automatically.

  • Can I use this module to troubleshoot "Node Offline" alarms?

    Yes. A failing KLCN Coax Assembly often triggers intermittent "Node Offline" or "Cable Fail" status messages. Replacing a suspected unit with a Brand New 51304544-100 immediately isolates whether the issue resides in the node hardware or the external trunk cable.

  • What are the primary precautions for handling this module?

    Since this is a sensitive RF communication card, you must strictly follow ESD (Electrostatic Discharge) procedures. Furthermore, ensure you use a calibrated torque tool for the coaxial connections to avoid over-tightening, which can damage the assembly's internal impedance traces.

  • How do I confirm this part is genuine Honeywell stock?

    Every unit arrives in its original Honeywell industrial antistatic packaging with a unique, verifiable serial number. The pristine condition of the gold edge connectors and the presence of factory-stamped batch codes confirm its status as a zero-hour original part.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more
Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Modern manufacturing is undergoing a rapid technological transformation driven by Industry 4.0 innovations. Technologies like Artificial Intelligence (AI), Machine Learning (ML), and the Industrial Internet of Things (IIoT) are dominating discussions across the factory automation sector. Consequently, many engineers wonder if these advanced digital tools will eventually replace traditional Programmable Logic Controllers (PLCs). However, evaluating the core physics of industrial operations reveals a very different reality for control systems.

Read more