Product Details

The Honeywell 51301880-100, also cataloged as the 51301880-100 Thermocouple Multiplexer Terminal Board, operates as a dedicated hardware component for low-millivolt signal termination and field thermocouple signal conditioning within Honeywell LE PIU, Experion PKS, and TDC 3000 network platforms.

Hardware Specifications

Parameter Specification
Model 51301880-100
Brand Honeywell
Origin USA
Weight 1.6 lbs
Dimensions Standard terminal board footprint
Operating Temp 0 to +60 deg C
Power Consumption Passive field termination assembly
Board Assembly Reference 51301881-100 Rev E
Function Thermocouple Multiplexer Terminal Board
Signal Input Type Low-millivolt Thermocouple Signals
Input Capacity Up to 16 thermocouple inputs (with relay board)
Cold Junction Compensation Integrated Cold Junction Reference (CJR)
Mounting Type Panel or rack-mounted
Field Wiring Interface Screw terminals
PCB Construction Industrial-grade PCB with protective conformal coating

Cold Junction Compensation and Channel-to-Channel Isolation

The board features an integrated Cold Junction Reference (CJR) block designed to perform precise temperature compensation directly at the field wiring interface point. Internal channel-to-channel isolation pathways decoupling thermocouple signals reduce ground loop interference and mitigate common-mode noise across all 16 input channels. The circuit board layout maintains thermoelectric EMF stability before routing multiplexed analog voltage signals through 4-20 mA HART and millivolt processing stages within the host system card cage.

Frequently Asked Questions

Q: How is thermal gradient error minimized across the field terminal blocks?

A: Cold Junction Compensation (CJC) thermistor circuitry is embedded in close physical proximity to the screw terminal rows, continuously measuring local block temperature to correct millivolt offset calculations in real time.

Q: Does the terminal board require an external power supply for signal processing?

A: No, the 51301880-100 is a passive field interface board that draws required reference voltage directly from the interconnected low-energy Process Interface Unit (LE PIU) or relay card assembly.

Field Installation Guidelines

  1. Mount the assembly on a flat enclosure panel or standard rack frame using ground-bonded mounting hardware to establish continuous earth ground.
  2. Route thermocouple extension wire pairs directly to designated terminal screw blocks, taking care to observe correct wire polarity (+ and - leads) for the specified thermocouple type.
  3. Ensure shield drain wires are tied to the local grounding bar at one point only to avoid introducing ground loops into millivolt signal paths.
  4. Verify all terminal block screws are torqued according to cabinet wiring standards to prevent resistance shifts at contact points.


Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more