Only 10 left - Selling fast

PRODUCT SKU : 10018/E/E

PRODUCT TYPE : Ethernet Communication Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 10018/E/E serves as a core Ethernet communication interface within the Fail Safe Control (FSC) system architecture. This module enables high-speed data exchange between the safety controller and external networks, ensuring real-time monitoring and diagnostic reporting for critical safety-instrumented functions (SIF). Although the manufacturer has discontinued the FSC line, we supply this unit in 100% Brand New, original factory condition, allowing you to maintain your certified safety systems without undergoing an expensive and time-consuming full-system migration.

Technical Specifications

The 10018/E/E provides the structural backbone for network integration in high-integrity environments:

Parameter Specification
System Architecture Fail Safe Control (FSC)
Communication Protocol Ethernet
Module Category Communication / Hardware Structure
Physical Interface RJ45 / Standard Network Port
Weight 2.00 lbs (0.91 kg)
Mounting FSC System Rack / Chassis Mount
System Compatibility Honeywell FSC Safety Systems
Lifecycle Status Discontinued by Manufacturer (Supported via New-Old Stock)

Engineering Advantages

  • High-Integrity Data Transmission: The 10018/E/E handles critical safety data packets with minimal latency. It ensures that the safety logic solver communicates state changes to the HMI or Distributed Control System (DCS) without interruption, which is vital for Emergency Shutdown (ESD) applications.

  • Galvanic Isolation: The module incorporates robust internal isolation to prevent electrical transients from the network side from reaching the safety backplane. This hardware-level protection secures the processor from external surges and ground loops.

  • Seamless Legacy Integration: This module fits directly into the existing FSC hardware structure. It utilizes standard configuration parameters, allowing engineers to replace faulty network modules without rewriting the underlying safety application or modifying the rack's physical wiring.

  • EMI/RFI Shielding: The module features a heavy-duty metal enclosure that mitigates electromagnetic interference. This design ensures stable Ethernet performance even when installed in close proximity to high-voltage switchgear or variable frequency drives (VFDs).

FAQs

Q: Can the 10018/E/E replace older non-Ethernet FSC communication cards?

A: This module specifically supports Ethernet-based communication. If you are upgrading from serial-based communication, you must verify your FSC system firmware version and network configuration to ensure compatibility with the Ethernet protocol.

Q: Does this module require specialized software for IP address configuration?

A: Yes. You configure the 10018/E/E through the Honeywell FSC programming environment. You must assign a static IP address to ensure persistent communication within the safety network.

Q: Is this a refurbished or pull-off unit?

A: No. We guarantee this 10018/E/E is 100% Brand New. We specialize in providing unused, original factory hardware to ensure your Safety Instrumented System (SIS) maintains its original reliability ratings.

Q: What are the installation requirements for heat dissipation?

A: Ensure the FSC rack has adequate clearance for vertical airflow. The 10018/E/E relies on natural convection cooling; therefore, maintaining clear ventilation paths within the cabinet prevents thermal degradation of the internal communication chips.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more