Description

The HIMA X-CB 008 04 is a high-reliability connection backplane designed to interconnect CPU units, I/O modules, power supplies, and communication components within the HIMax safety PLC system. It provides the essential backbone for electrical and mechanical integration, ensuring continuous data exchange and stable power distribution across all modules.

Built with industrial-grade materials, the X-CB 008 04 withstands vibration, temperature variation, and electrical interference, maintaining operational integrity in demanding environments such as oil and gas, chemical processing, and power generation. Its plug-in connection design simplifies both installation and maintenance, reducing system downtime and improving overall reliability.

Technical Specifications

  • Manufacturer: HIMA

  • Model: X-CB 008 04

  • Product Type: Backplane / Connector Board

  • System Compatibility: HIMax safety PLC platform

  • Supported Modules: CPU, I/O, communication, and power supply units

  • Connection Type: Plug-in screw terminal system

  • Redundancy Design: Dual-channel connection for continuous operation

  • Supported Signal Types: Digital (DI/DO) and Analog (AI/AO)

  • Cable Length (max): Up to 100 m depending on module configuration

  • Electrical Isolation: Independent signal paths to prevent crosstalk

  • Bus System: HIMax system communication bus

  • Power Distribution: 24 V DC nominal routed through internal backplane

  • Mounting Options: DIN rail or panel-mounted installation

  • Housing Material: Flame-retardant, industrial-grade thermoplastic

  • Dimensions (W × H × D): 160 × 100 × 40 mm

  • Weight: 0.45 kg

  • Operating Temperature: –20°C to +70°C

  • Storage Temperature: –40°C to +85°C

  • Humidity Range: 5–95% RH, non-condensing

  • Vibration Resistance: IEC 60068-2-6, 5–150 Hz, 1 g

  • Environmental Compliance: RoHS, REACH

  • Electromagnetic Compatibility: EN 61326-1 compliant

Features

  • Centralized Connectivity: Provides reliable mechanical and electrical links for all HIMax modules.

  • Redundant Architecture: Dual safety paths maintain system operation during component failure.

  • Simplified Maintenance: Plug-in terminal structure enables quick module replacement.

  • Signal Flexibility: Compatible with both analog and digital input/output channels.

  • Industrial Durability: Resistant to vibration, heat, and EMI for long-term stability.

  • Modular Design: Scalable integration of CPUs, I/O, and communication units.

Applications

  • Safety instrumented systems (SIS) in oil and gas refineries

  • Chemical and petrochemical process control networks

  • Power generation and energy distribution plants

  • Industrial automation requiring continuous safety monitoring

  • Redundant PLC architectures in mission-critical environments

FAQ

Q1: Which HIMax modules can be mounted on the X-CB 00804?
A1: It supports CPU units, I/O cards, power modules, and communication interfaces.

Q2: Does it support redundant operation?
A2: Yes, dual redundant connection paths ensure uninterrupted functionality.

Q3: Is it compatible with both analog and digital signals?
A3: Yes, the backplane supports DI/DO and AI/AO signal types.

Q4: What type of environment can it operate in?
A4: It is built for harsh industrial conditions with high vibration and temperature variation.

Q5: How is the board installed?
A5: It can be mounted on DIN rails or fixed directly within control panels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more