GE WESDAC D20 C Analog Digital I/O Module
GE WESDAC D20 C Analog Digital I/O Module
GE WESDAC D20 C Analog Digital I/O Module

GE WESDAC D20 C Analog Digital I/O Module


Only 10 left - Selling fast

PRODUCT SKU : WESDAC D20C

PRODUCT TYPE : Analog Digital I/O Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for analog data acquisition and discrete relay control execution in electrical substation automation platforms, the GE WESDAC D20 C (GE D20C Analog Digital I/O Module) provides direct physical/electrical execution. The hardware integrates localized multi-channel monitoring and command-relay routing within a single distributed architecture node, maintaining deterministic processing intervals across all configured internal circuits.

Hardware Specifications

Parameter Specification
Model WESDAC D20 C (D20C)
Brand GE (General Electric)
Origin United States
Weight 2.5 kg (Approximate based on physical frame assembly)
Dimensions 19.0" x 5.25" x 2.5" (Standard 19-inch rackmount width)
Operating Temp -20 to +70 deg C (Standard industrial substation rating)
Power Consumption 5 W typical (20-60 VDC range), 11 W maximum with 24 VDC contact wetting active
Processor Type 8-bit Freescale 68HC11 MPU
Clock Speed 2 MHz MPU clock
Onboard Memory 24 KB EPROM, 32 KB static RAM, 512 bytes EEPROM
Analog Inputs 16 bipolar, differential inputs via plug-in daughter board
Analog Accuracy +/-0.05% for voltage configurations, +/-0.1% for current configurations
Temperature Drift +/-10 ppm per deg C
ADC Resolution 14 bits plus sign bit
Scan Conversion Rate 275 ms for 16 inputs @ 60 Hz line filter, 328 ms for 16 inputs @ 50 Hz line filter
Dynamic Input Range 125% of normalized full-scale inputs
Control Outputs 8 interposing relays plus 2 Master Trip/Close relays, or 8 isolated Form C contacts
Contact Switching Rating 60 W maximum, 3 A maximum, 220 VDC maximum (single Form-C or -A contact)
Output Duration Control Programmable 1 to 215 ms (1 ms intervals) or 1 to 215 s (1 s intervals)
Coil Integrity Check Continuous status loop verification executed every 500 microseconds
Input Isolation Rating 1500 Vrms component isolation, 1000 VDC dielectric rating
Network Communication 2 dedicated D.20 Link ports, 1 local RS-232 maintenance port at 9600 baud
Local Interface Physical toggle switch for local enable/disable authorization

Industrial Control & Firmware Flash Compatibility

The architectural interface relies on low-latency backplane bus execution profiles synchronized directly with the Freescale MPU pipeline. Field deployment requires absolute verification of firmware flash compatibility versions when linking the sub-assembly to the primary D20 processor node. Operating parameters dictate that EEPROM allocation memory must match the system image map to preserve local calibration curves during hot-swap recovery cycles. If firmware revisions deviate from the core processing unit base level, communications across the dual D.20 Link ports will drop packets, triggering a hardware-driven local lockout state.

Frequently Asked Questions

Q: How does the local enable/disable switch alter the physical command state of the control relays?

A: The physical toggle switch acts as a hardware-level interlock that isolates the drive coils of the 8 control relays and the 2 Master Trip/Close relays from the internal logic. When toggled to the disable position, it prevents all remote execution commands from activating the output circuits, providing an absolute safety break for local physical maintenance.

Q: What is the mechanical and electrical isolation threshold between the analog processing electronics and the field wiring terminations?

A: The module incorporates optocouplers and magnetic transformers providing a component isolation rating of 1500 Vrms and a dielectric breakdown limit of 1000 VDC. This prevents high-voltage transient surges originating on external 4-20 mA or voltage loops from cross-propagating into the internal 8-bit MPU logic bus.

Q: How does the hardware handle scanning cycles if the grid frequency fluctuates between 50 Hz and 60 Hz?

A: The analog-to-digital converter relies on fixed hardware integration filters tailored to the line frequency. If configured for 60 Hz, the execution time for all 16 differential channels requires exactly 275 ms; if configured for 50 Hz, the integration window expands to 328 ms to suppress ambient line noise. Discrepancies between physical frequency and software filter settings degrade accuracy margins beyond the stated specifications.

Field Installation Guidelines

  • Rack Mounting & Thermal Dissipation: The unit must be secured within a standard 19-inch electronic enclosure using high-tensile machine screws. Maintain a minimum of 1U (44.45 mm) structural clearance above and below the assembly frame to permit unrestricted natural convection cooling across the internal daughterboard heat sinks.
  • Field Wiring and Shielding Terminations: All analog differential signals must be routed using twisted-pair cables with overall braided foil shields. Ground all shield tails exclusively at the master substation terminal ground busbar; do not daisy-chain shields or ground them at both ends to eliminate ground loop current injection into the 14-bit ADC stage.
  • Relay Contact Arc Suppression: For inductive DC loads connected to the Form C output relays, external flyback diodes must be reverse-biased across the external load terminal points. Failure to deploy suppression will induce high-voltage arcing during contact break sequences, accelerating mechanical pitting and degrading the 60 W maximum switching limit.
  • Power Input Grounding: The 20-60 VDC primary power supply lines must be routed through a dedicated circuit breaker. Connect the chassis ground terminal directly to the panel frame using a low-impedance copper conductor with a minimum cross-sectional area of 2.5 mm squared.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more