Product Description

The IS220PPRFH1B PROFIBUS Master Gateway Module is part of GE’s Mark VIe Series, engineered to provide deterministic and high-speed communication between turbine controllers and PROFIBUS-DP field devices. Designed for large-scale process control and power generation environments, this module ensures seamless integration of distributed I/O, sensors, and actuators into turbine automation systems.

Technical Specifications

  • Model: IS220PPRFH1B

  • Series/Family: Mark VIe (IS200/IS220 Series)

  • Product Type: PROFIBUS Master Gateway I/O Module

  • Functional Acronym: PPRF

  • Manufacturer: GE Intelligent Platforms (General Electric)

  • Interface: PROFIBUS via RS-485 (COM-C Module)

  • Master Type: DPV0, Class 1

  • Slave Capacity: Up to 125 devices

  • Data Throughput per Slave: 244 bytes input / 244 bytes output

  • Transmission Speed: 9.6 kbaud to 12 Mbaud

  • Redundancy Options: Single Ethernet, Dual Ethernet, Pack Hot-Backup Ethernet (2-port)

  • Input Voltage: Nominal 28 V DC

  • Maximum Input Current: 0.18 A DC

  • Operating Temperature Range: -20°C to +55°C (-4°F to +131°F)

  • Certifications:

    • ATEX Zone 2 Group IIC (UL DEMKO 12 ATEX 1114875X)

    • UL E207685

  • PCB Protection: Conformal coating for environmental durability

Application Scenarios

  • Wind turbine control systems requiring PROFIBUS-DP integration

  • Power generation plants with distributed I/O networks

  • Industrial automation requiring deterministic communication with sensors and actuators

FAQ

Q: How many PROFIBUS devices can be connected?  A: The module supports up to 125 slave devices with full DPV0 Class 1 master functionality.

Q: What redundancy options are available?  A: Single Ethernet, dual Ethernet, and hot-backup Ethernet configurations are supported for fault tolerance.

Q: Is this module suitable for hazardous environments?  A: Yes, it is ATEX Zone 2 certified for use in industrial environments with explosive atmospheres.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more