PRODUCT SKU : IC200CHS003K

PRODUCT TYPE : I/O Terminal Bases

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IC200CHS003K, also cataloged as the IC200CHS003 Input/Output Carrier, operates as a dedicated hardware component for field signal termination and backplane interface mounting within GE VersaMax control networks.

Hardware Specifications

Parameter Specification
Model IC200CHS003K
Brand GE (GE Fanuc / Emerson)
Origin USA
Weight 0.11 kg (0.25 lbs)
Power Consumption Passive backplane power routing
Wiring Termination Style Connector style (36-pin connector)
Max I/O Points Up to 32 input/output points
Rated Current Per Point 2 A per point
Rated Current Power/Ground 8 A per power and ground connection
Transient Voltage Rating 300 VAC maximum
Contact Resistance Less than 10 milliohms
Degree of Protection IP20
Housing Material ABS plastic
Mounting Type DIN rail mount (Vertical orientation)

Deterministic Network Execution & Backplane Velocity

The IC200CHS003K carrier provides the physical backplane interface and structural mounting base for VersaMax I/O modules, establishing high-velocity backplane bus communication routes directly to the main CPU or interface unit. By managing up to 32 I/O points via an integrated 36-pin field connector, the carrier maintains contact resistance below 10 milliohms to preserve signal fidelity during real-time data acquisition cycles.

Full compatibility with Profinet / EtherNet/IP deterministic networks is achieved when paired with active network interface modules, facilitating flexible I/O density scaling across expanded rail assemblies. The mechanical architecture enforces tight firmware flash compatibility across installed field modules while providing up to 4 common power connections rated for 8 A power and ground distribution.

Frequently Asked Questions

Q: What is the maximum current capacity for individual I/O channels and power terminals on the IC200CHS003K carrier?

A: Individual I/O points are rated at 2 A per channel, while common power and ground connections support up to 8 A per point.

Q: How are field wiring connections terminated on the IC200CHS003K module?

A: Field connections are established via an integrated 36-pin connector, enabling direct harness connection rather than individual screw terminal wiring.

Q: Is live insertion or extraction of I/O modules supported on this carrier?

A: Hot-swapping depends on the system controller and module capabilities; field power and backplane supply must be isolated if non-hot-swappable modules are mounted on the carrier.

Field Installation Guidelines

  1. Power Isolation: Disconnect and lock out all 24 VDC/120 VAC field power and backplane power supplies before installing or servicing the carrier unit.
  2. DIN Rail Mounting: Snap the carrier onto a standard 35 mm DIN rail in a vertical mounting orientation, ensuring the rear locking tab fully engages the rail lip.
  3. Earthing and Grounding: Ensure direct metal-to-metal contact with a grounded DIN rail to establish chassis grounding for transient suppression up to 300 VAC.
  4. Harness Connection: Align the 36-pin field harness connector carefully with the header on the carrier and press firmly until side retaining latches lock into position.
  5. Module Seating: Slide the corresponding VersaMax I/O module vertically into the carrier keying tracks until the backplane connector fully mates and latching mechanisms lock.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Centralized vs Decentralized Automation Systems: Architectural Trade-Offs in Modern Industrial Control

Centralized vs Decentralized Automation Systems: Architectural Trade-Offs in Modern Industrial Control

Industrial automation relies heavily on robust control architectures to manage complex processes efficiently. Engineers must choose between centralized and decentralized topologies when designing plant automation. This decision directly impacts system reliability, scalability, and long-term maintenance costs.

Read more
Engineering a Process Control System Philosophy: Principles and Operational Impact

Engineering a Process Control System Philosophy: Principles and Operational Impact

A Process Control System (PCS) Philosophy serves as the foundational blueprint for modern plant engineering. During the design and construction phases, this document establishes clear guidelines for instrumentation and control (I&C) teams. Consequently, a well-defined philosophy directly dictates overall operational stability, maintenance efficiency, and future expansion capabilities across heavy process industries.

Read more
Engineering MCC Signal Interface Terminations in Modern Process Automation

Engineering MCC Signal Interface Terminations in Modern Process Automation

Industrial manufacturing plants rely on Motor Control Centers (MCC) to drive critical electrical loads. Plant engineers must interface these MCC motor starters and drives with central control systems. Standardizing the Signal Interface Termination (SIT) architecture ensures seamless command delivery and feedback monitoring between field equipment and process automation platforms.

Read more