PRODUCT SKU : IC200UDD164

PRODUCT TYPE : Micro Controller

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax IC200UDR164 is a microcontroller module designed for industrial automation systems requiring high-density I/O and relay-based output control. With 64 total I/O points, dual voltage input support, and robust relay outputs, it provides reliable performance for distributed control applications. Its design includes strong isolation, fast response, and high inrush current handling, making it suitable for demanding environments.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC200UDR164

  • Product Line: VersaMax

  • Product Type: Micro Controller

  • Weight: 2.00 lbs (0.91 kg)

  • Inputs: 40 discrete inputs

  • Outputs: 24 relay outputs (SPST, normally open)

  • Total I/O Points: 64

  • Relay Load Capacity: 2 A at 24 VDC or 240 VAC (resistive load)

  • Input Voltage Range: 100–240 VAC

  • Input Frequency Range: 50–60 Hz

  • Input Logic: Positive or negative logic supported

  • Hold-up Time:

    • 10 ms at 85–100 VAC

    • 20 ms at 100–265 VAC

  • Inrush Current:

    • 40 A at 265 VAC

    • 30 A at 200 VAC

Application Scenarios

The IC200UDR164 is ideal for machine automation, process control, and distributed PLC systems requiring mixed input/output density. Its relay outputs make it suitable for controlling motors, solenoids, and other resistive loads in industrial environments.

FAQ

Q: How many I/O points does the IC200UDR164 provide?  A: It supports 64 total I/O points (40 inputs and 24 relay outputs).

Q: What type of relay outputs are included?  A: Single Pole, Single Throw (SPST) normally open relay outputs.

Q: What is the maximum resistive load supported?  A: 2 A at 24 VDC or 240 VAC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more