Product Description

The GE Fanuc VersaMax IC200MDL744 is discrete output modules designed for VersaMax PLC systems. They provide 32 output points divided into two groups, supporting multiple DC voltage ranges for flexible control applications. With robust isolation between groups, LED indicators for each channel, and high current capacity, these modules deliver reliable performance in demanding automation environments.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC200MDL744

  • Product Line: VersaMax

  • Product Type: Discrete Output Module

  • Weight: 1.00 lbs (0.45 kg)

  • Number of Outputs: 32 points, organized into 2 groups

  • Output Voltage Ranges:

    • TTL mode: 4.75–5.25 VDC (nominal 5 VDC)

    • Standard mode: 10.2–30 VDC (nominal 12/24 VDC)

  • Output Current Capacity: Up to 5 A per point

  • Group-to-Group Isolation: 250 VAC continuous, 1500 VAC for 1 minute

  • Point-to-Point Isolation: None

  • Indicators: One LED per output, plus OK and FLD PWR LEDs

  • Backplane Current Consumption: 140 mA at 5 VDC

  • Protection: No internal fuse (external protection required)

  • Module ID: 80808080

Application Scenarios

The IC200MDL744 is suitable for machine control, process automation, and distributed I/O systems requiring multiple DC outputs. Its dual voltage support makes it versatile for applications involving mixed signal levels.

FAQ

Q: How many outputs does the IC200MDL744 provide?  A: It offers 32 discrete outputs divided into two groups.

Q: What isolation is provided?  A: Group-to-group isolation is rated at 250 VAC continuous and 1500 VAC for one minute.

Q: Does the module include internal fuses?  A: No, external protection must be provided.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more