Product Description

The GE Fanuc VersaMax IC200CHS005 is a spring-clamp terminal I/O carrier module designed for secure and efficient wiring in VersaMax PLC systems. It supports 32 I/O points with 36 spring-style terminals, ensuring reliable electrical connections without the need for screw tightening. With robust isolation, high current capacity per point, and compact construction, this carrier provides dependable integration for industrial automation applications.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC200CHS005

  • Product Line: VersaMax

  • Product Type: Spring-Style Terminal I/O Carrier

  • Weight: 0.88 lbs (0.40 kg)

  • Spring-Clamp Terminals: 36

  • I/O Points Supported: 32

  • Terminal Torque: 0.37–0.45 lb-ft

  • Current Capacity per Point: 2 A

  • Maximum Point Voltage: 264 VAC

  • Common/Power Connections: 4

Application Scenarios

The IC200CHS005 is ideal for control panels and distributed I/O systems where quick wiring and secure connections are required. Its spring-style terminals reduce installation time and improve reliability in environments subject to vibration or frequent maintenance.

FAQ

Q: How many I/O points does the IC200CHS005 support?  A: It supports 32 I/O points with 36 spring-style terminals.

Q: What is the maximum voltage rating per point?  A: Each point can handle up to 264 VAC.

Q: What type of connections are included?  A: Four common/power connections are integrated into the carrier.

Comparison with Similar Models

  • IC200CHS002: Screw-style terminal carrier, suitable for traditional wiring.

  • IC200CHS006: Higher-density carrier for larger systems. The IC200CHS005 offers a balance of compact design and spring-style convenience for mid-range applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more