Skip to content

What are you looking for?


You may also like

GE F650BABF1G1HIS6E Multilin F650 Feeder Protection RelayGE F650BABF1G1HIS6E Multilin F650 Feeder Protection RelayGE F650BABF1G1HIS6E Multilin F650 Feeder Protection Relay
GE F650BABF1G1HIS6E Multilin F650 Feeder Protection Relay
GE F650BABF1G1HIS6E Multilin F650 Feeder Protection Relay
GE F650BABF1G1HIS6E Multilin F650 Feeder Protection Relay

GE F650BABF1G1HIS6E Multilin F650 Feeder Protection Relay


Only 10 left - Selling fast

PRODUCT SKU : F650BABF1G1HIS6E

PRODUCT TYPE : Feeder Protection Relays

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-performance feeder protection and bay control execution within electrical distribution networks, the GE F650BABF1G1HIS6E (F650 Feeder Protection Relay) provides direct physical/electrical execution. The hardware processes 16 digital inputs and 8 outputs via dedicated I/O slot mapping, operating over redundant 10/100 Base TX Ethernet and redundant glass fiber optic serial links. It executes protection algorithms and real-time bay automation under multiple industrial communication protocols.

Hardware Specifications

Parameter Specification
Model F650BABF1G1HIS6E
Brand GE Multilin
Origin Factory technical specifications apply
Weight Unit specific / Enclosure dependent
Dimensions Standard F650 panel mount footprint
Operating Temp Industrial grade classification
Power Consumption Dependent on active auxiliary voltage rail
Display Type Graphic Display with IEC Symbols
Rear Serial Comm Redundant Glass Fiber Optic
Rear Ethernet Comm Redundant 10/100 Base TX with IEEE 1588 PTP
I/O Card Slot F 16 Digital Inputs + 8 Outputs
I/O Card Slot G None
Auxiliary Voltage High Range (110-250 VDC)
System Language English/English
Protocol Support IEC 61850 Edition 2, Modbus RTU & TCP/IP, DNP 3.0 Level 2, IEC 60870-5-104
Conformal Coating Harsh (Chemical) Environment Standard
Front Interface Enhanced Display with Front USB Port

Firmware Flash Compatibility and Deterministic Network Behavior

The hardware subsystem enforces synchronous sub-millisecond precision timing across deterministic Ethernet networks utilizing the integrated IEEE 1588 Precision Time Protocol (PTP). Internal processing blocks maintain strict firmware flash compatibility across standard protection algorithms, preventing execution latency during high-density concurrent I/O polling. Communication routing is isolated on the backplane level to prevent external data queries from interrupting real-time tripping functions or relay logic processing loops.

Frequently Asked Questions

Q: Does this specific model support live hot-swapping of the I/O or communication boards?

A: No. The internal backplane bus requires complete isolation from the auxiliary voltage supply (110-250 VDC) prior to extracting or inserting any modular boards to prevent transient electrical damage or corrupted relay states.

Q: How is the network communication redundancy managed by this module?

A: The module utilizes a redundant 10/100 Base TX Ethernet configuration running concurrent protocol routing. If a physical link failure occurs on one channel, communication switches to the backup link without disrupting internal relay logic processing or event logging.

Field Installation Guidelines

  • Grounding Protocol: Secure a low-impedance copper ground strap directly from the chassis grounding terminal to the central substation ground bus bar before applying auxiliary power.
  • Shielding Rules: All digital input and RS485 communication signaling lines must utilize twisted-shielded pair cabling. Connect the shield to the ground at the enclosure entry point only to prevent ground loops.
  • Wiring Separation: Maintain independent cable routing conduits for the high-voltage auxiliary power feed (110-250 VDC) and low-voltage signaling/fiber connections to mitigate electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential SCADA Features for Modern IoT-Enabled Industrial Automation

Essential SCADA Features for Modern IoT-Enabled Industrial Automation

The convergence of traditional SCADA systems with the Industrial Internet of Things (IIoT) has redefined factory automation. Choosing a robust platform requires more than just standard monitoring capabilities. In this era of Industry 4.0, your supervisory system must bridge the gap between legacy control systems and enterprise-level data integration.

Read more
Selecting Rockwell Automation Allen-Bradley PLCs for Small and Mid-Sized Applications

Selecting Rockwell Automation Allen-Bradley PLCs for Small and Mid-Sized Applications

Rockwell Automation remains a cornerstone in global industrial automation. Their Allen-Bradley brand provides a comprehensive portfolio of control systems designed to meet diverse production requirements. Choosing the right programmable logic controller (PLC) is critical for system reliability and scalability. This guide analyzes the Micro and Compact Logix families to help you select the optimal solution for small and medium-scale projects.

Read more
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more