Skip to content

What are you looking for?


You may also like

FS-IOCHAS-0001R | Honeywell | I/O Chassis for Redundant ModuleFS-IOCHAS-0001R | Honeywell | I/O Chassis for Redundant ModuleFS-IOCHAS-0001R | Honeywell | I/O Chassis for Redundant Module
FS-IOCHAS-0001R | Honeywell | I/O Chassis for Redundant Module
FS-IOCHAS-0001R | Honeywell | I/O Chassis for Redundant Module
FS-IOCHAS-0001R | Honeywell | I/O Chassis for Redundant Module

FS-IOCHAS-0001R | Honeywell | I/O Chassis for Redundant Module


Only 10 left - Selling fast

PRODUCT SKU : FS-IOCHAS-0001R

PRODUCT TYPE : Chassis Assemblies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for redundant I/O module mounting in Honeywell control system hardware platforms, the Honeywell FS-IOCHAS-0001R (FS-IOCHAS-0001R I/O Chassis for Redundant Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model FS-IOCHAS-0001R
Brand Honeywell
Origin USA
Weight 7.6 kg
Dimensions 48.2 x 30 x 22 cm
Operating Temp -40 to 70 deg C
Power Consumption 5 V-1: 35 mA; 5 V-2: 35 mA
Input Voltage 24 VDC (18 to 36 VDC)
Module Capacity Up to 9 pairs of redundant I/O modules
Relative Humidity 5 to 95% RH, condensing
Vibration Resistance 5g @ 10 to 500 Hz (IEC 60068-2-6)

Channel-to-Channel Isolation and Module Integration

The FS-IOCHAS-0001R chassis establishes the physical and electrical backplane infrastructure required to house up to 9 pairs of redundant I/O modules. The internal bus routing distributes primary 24 VDC supply voltage while powering dual 5 V rail lines for slot logic circuits. Designed to support DCS processing topologies with 4-20 mA HART loop protocol connectivity, the backplane preserves strict channel-to-channel isolation between adjacent module slots, eliminating ground loop current propagation and minimizing cross-talk during parallel data transmission across the control network.

Frequently Asked Questions

Q: How many redundant I/O module pairs can be seated within a single FS-IOCHAS-0001R backplane frame?

A: The chassis provides physical slots and dedicated backplane connections to support up to 9 pairs of redundant I/O modules simultaneously.

Q: What are the backplane current draw ratings on the internal 5 V DC logic supply rails?

A: The chassis backplane draws a nominal current of 35 mA on the 5 V-1 rail and 35 mA on the redundant 5 V-2 rail under idle chassis load conditions.

Q: Does the chassis perform onboard signal conversion or execution logic for field I/O channels?

A: No, the chassis acts purely as a passive physical mounting structure and electrical distribution interconnect; it executes no active signal processing or control logic.

Field Installation Guidelines

  1. Mount the chassis securely into a 19-inch subrack frame or panel using all four corner mounting points.
  2. Connect the main cabinet protective earth (PE) strap directly to the chassis grounding lug to establish low-impedance earthing.
  3. Verify input power polarity on the 24 VDC terminal block (18-36 VDC range) before applying primary power.
  4. Segregate high-voltage AC lines from field signal cabling, using separate wiring channels inside the cabinet.
  5. Inspect backplane card-edge sockets for debris or bent pins prior to inserting redundant I/O modules into their designated slots.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more