Skip to content

What are you looking for?


You may also like

FS-DCOM-232/485 Safety Manager Communication Interface Module | HoneywellFS-DCOM-232/485 Safety Manager Communication Interface Module | HoneywellFS-DCOM-232/485 Safety Manager Communication Interface Module | Honeywell
FS-DCOM-232/485 Safety Manager Communication Interface Module | Honeywell
FS-DCOM-232/485 Safety Manager Communication Interface Module | Honeywell
FS-DCOM-232/485 Safety Manager Communication Interface Module | Honeywell

FS-DCOM-232/485 Safety Manager Communication Interface Module | Honeywell


Only 10 left - Selling fast

PRODUCT SKU : FS-DCOM-232/485

PRODUCT TYPE : Communication Interface Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell FS-DCOM-232/485 functions as a high-integrity Communication Interface Module within the Honeywell Safety Manager (SM) and FSC architectures. It facilitates the transparent exchange of serial data between the Control Processor and external third-party devices, such as PLCs, HMIs, or SCADA systems. We supply this module as 100% Brand New Original equipment, ensuring your safety-critical communication links adhere to the rigorous standards required for TUV and FM-certified environments.

Technical Specifications

The FS-DCOM-232/485 provides dual-protocol support with high-speed throughput capabilities:

Feature Specification Details
Manufacturer Honeywell
Model Number FS-DCOM-232/485
Input Voltage 5 Vdc ±5% (Supplied by Control Processor)
Input Current Max 500 mA
RS232 Baudrate 0—250 kBaud (EIA/TIA-232 Levels)
RS485/422 Baudrate 0—2 MBaud (EIA/TIA-485-A Levels)
Encoding Support Transparent, FM0, FM1, or Manchester Coded
Module Dimensions 110 × 70 × 61 mm
Mounting DIN EN Rails TS32 / TS35 × 7.5
Condition 100% Brand New Original

Engineering Advantages

  • Multi-Protocol Versatility: This module supports RS232, RS422, and RS485 standards. This consolidation allows engineers to interface with a wide array of legacy and modern peripherals without stocking multiple specific interface cards.

  • High-Speed Transparent Coding: The module handles data rates up to 2 MBaud for RS485/422 links. It supports Manchester and FM0/FM1 coding, which ensures robust clock recovery and data synchronization over long-distance serial runs.

  • Processor-Integrated Power: The FS-DCOM-232/485 draws its 5 Vdc power directly from the Safety Manager Control Processor. This eliminates the need for external field power supplies, reducing potential failure points and simplifying the overall cabinet wiring architecture.

  • DIN Rail Optimization: The compact footprint and standard TS32/TS35 rail mounting simplify installation in densely packed safety cabinets. The module requires only 117 mm of rail length, effectively maximizing I/O density.

  • Safety-Certified Reliability: With TUV and FM approvals, this interface meets the global requirements for Safety Instrumented Systems (SIS). It maintains the deterministic communication necessary for Emergency Shutdown (ESD) and Fire & Gas (F&G) applications.

FAQs

  • Can the FS-DCOM-232/485 handle RS422 and RS485 simultaneously?

    The hardware design shares the output levels for RS485 and RS422 protocols (EIA/TIA-485-A). While the module is highly versatile, you must configure the wiring and software parameters to match the specific physical layer of your connected device.

  • Does this module require a separate external power supply?

    No. The module receives its required 5 Vdc (up to 500 mA) directly from the Honeywell Control Processor. This ensures that the communication interface remains synchronized with the processor's power state.

  • What are the recommended cable types for high-speed 2 MBaud transmission?

    To achieve the maximum 2 MBaud rate on RS485/422, you must use high-quality shielded twisted-pair (STP) cabling with appropriate characteristic impedance. This minimizes signal reflection and electromagnetic susceptibility.

  • How do I verify the authenticity of this module?

    Genuine FS-DCOM-232/485 modules feature clear Honeywell branding, certified approval stamps (TUV, FM, etc.), and arrive in original anti-static factory packaging. Every unit we ship is 100% Brand New Original with full traceability.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more