Product Details

The Foxboro P0916FH, also cataloged as the P0916FH Cable Assembly, operates as a dedicated hardware component for interconnecting fieldbus modules and termination assemblies within Foxboro I/A Series system racks. Configured as a 1 meter Type 4 terminal cable, it provides point-to-point wiring between FBM2xx series I/O modules and external field termination blocks to route analog and digital signals.

Hardware Specifications

Parameter Specification
Model P0916FH
Brand Foxboro
Origin USA
Weight 1.36 kg (3.00 lbs)
Dimensions 1 meter length
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive wiring assembly (0 W)
Cable Type Type 4 Terminal Cable
Compatibility FBM2xx Series Modules
Conductor Interface Multi-pin system connector

Channel-to-Channel Isolation and Loop Protocol Connectivity

The Foxboro P0916FH terminal cable retains internal conductor shielding and twisted-pair routing to prevent crosstalk between adjacent I/O channels. Integrated drain wires and galvanic isolation boundaries maintain signal accuracy across 4-20 mA HART loop protocol instruments and prevent cold junction compensation (CJC) thermal offset drift when routing temperature sensor field connections.

Frequently Asked Questions

Q: Which Foxboro modules are compatible with the P0916FH terminal cable?

A: The P0916FH is designed for direct interface with Foxboro FBM2xx series fieldbus modules and corresponding termination bases.

Q: Does the P0916FH cable support hot-swapping of connected FBM modules?

A: Yes, provided the connected FBM2xx module and baseplate support online insertion and removal, the cable connection remains static during module replacement.

Field Installation Guidelines

Ensure all power feeds to the targeted I/O baseplate are disconnected prior to installing or removing the P0916FH cable assembly. Inspect male and female pin assignments on both ends to verify alignment before mating connectors.

Press the multi-pin connectors firmly into the FBM2xx baseplate and termination assembly receptacles until side retention latches click into place. Maintain minimum bend radiuses along the 1 meter cable run within cabinet wire ducts, keeping signal wiring separated from high-voltage AC circuits. Fasten cable shield drain wires directly to the enclosure single-point ground bar. Where field cabling enters through conduit, verify that all NPT threaded entries maintain at least 5 full threads of engagement.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more