Foxboro FCP270 P0926MX I/A Series Fiber Optic Splitter/Combiner KitFoxboro FCP270 P0926MX I/A Series Fiber Optic Splitter/Combiner KitFoxboro FCP270 P0926MX I/A Series Fiber Optic Splitter/Combiner Kit
Foxboro FCP270 P0926MX I/A Series Fiber Optic Splitter/Combiner Kit
Foxboro FCP270 P0926MX I/A Series Fiber Optic Splitter/Combiner Kit
Foxboro FCP270 P0926MX I/A Series Fiber Optic Splitter/Combiner Kit

Foxboro FCP270 P0926MX I/A Series Fiber Optic Splitter/Combiner Kit


Only 10 left - Selling fast

PRODUCT SKU : FCP270 P0926MX

PRODUCT TYPE : Fiber Optic Splitter

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Foxboro FCP270 P0926MX (Alternative Part Number: 0SC-1801L) functions as a critical passive optical interface within the Foxboro Evo and I/A Series Distributed Control Systems. It facilitates the seamless splitting and combining of optical signals for FCP270 fault-tolerant processor pairs. This kit ensures that both processors in a redundant configuration receive identical data streams simultaneously, maintaining synchronized control logic. We supply this product as 100% Brand New and Original, guaranteeing factory-spec attenuation levels for mission-critical network stability.

Technical Specifications

Feature Specification Details
Manufacturer Foxboro (Schneider Electric)
Technology Passive Optical Prism (Non-powered)
Wavelength 850 nm / 1300 nm (Multi-mode)
Compatibility FCP270 Fault-Tolerant Pairs
Housing Construction Industrial-grade EMI/RFI Immune
Operating Temp -20°C to +70°C
Storage Temp -40°C to +85°C
Dimensions 115 mm x 45 mm x 32 mm
Weight 0.22 kg

Engineering Advantages

The P0926MX addresses specific physical layer challenges in high-availability DCS environments:

  • Zero Latency Signal Distribution: The passive prism technology eliminates electronic processing delays. The hardware splits the light beam at the speed of light, ensuring the standby processor remains perfectly "in-step" with the primary unit.

  • Maintenance-Free Operation: Because this unit requires no external power source, it removes a potential point of failure from the control loop. It operates continuously without firmware updates or electrical components that could fail due to power surges.

  • Superior Signal Integrity: High-precision optical alignment minimizes insertion loss. This low-attenuation design prevents signal "jitter" or data packet loss over extended fiber runs between control cabinets.

  • Environmental Immunity: The industrial-grade housing shields the optical path from electromagnetic interference (EMI) and radio frequency interference (RFI), making it ideal for installation near heavy machinery or high-voltage switchgear.

FAQs

  • Does the P0926MX require a separate power supply? No. The P0926MX utilizes passive optical prism technology. It functions entirely on the light energy provided by the FCP270 fiber ports, requiring no electrical input.

  • Can I use this kit with single-mode fiber systems? This specific model optimizes performance for 850 nm and 1300 nm multi-mode fiber. Using it with single-mode fiber will result in excessive signal loss and potential communication failure.

  • How does the P0926MX facilitate fault tolerance? The kit splits the incoming fieldbus signal into two identical paths. One path feeds the Primary FCP270 while the other feeds the Shadow (Standby) FCP270. This allows the Shadow processor to monitor all inputs in real-time for an instantaneous bumpless transfer if the Primary fails.

  • Is this unit compatible with the 0SC-1801L part number? Yes, the P0926MX and 0SC-1801L are functionally identical. We provide these units in Brand New condition to replace existing worn or damaged optical splitters in Foxboro Evo systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more