Product Details

The Honeywell FS-CCI-HSE-30, also cataloged as the 51506993-730 Safety Manager Ethernet Cable, operates as a dedicated hardware component for high-speed Ethernet data transmission up to 1 Gbps within Honeywell Experion and Safety Manager architectures. It provides shielded point-to-point interconnection between industrial switches and safety interface modules over a 30 m physical drop distance.

Hardware Specifications

Parameter Specification
Model FS-CCI-HSE-30 (51506993-730)
Brand Honeywell
Origin USA
Weight 0.2 kg
Dimensions Cable Length: 30 meters
Operating Temp -20 deg C to 60 deg C
Power Consumption Passive Component
Cable Type Shielded Twisted Pair (STP)
Conductor Material 24 AWG solid copper
Connector Type RJ45
Characteristic Impedance 100 Ohms
Maximum Data Rate 1 Gbps (Gigabit Ethernet)
Shielding Foil and braid EMI/RFI protection
Compliance Standards TIA/EIA-568-B.2, ISO/IEC 11801, EN 50173
Fire Rating Plenum-rated

Channel Isolation and HART Loop Protocol Interoperability

The Honeywell FS-CCI-HSE-30 cable assembly utilizes a dual-layer foil and braid shield structure to preserve channel-to-channel isolation parameters across dense cabinet wiring ducts. When deployed alongside high-density 4-20 mA HART loop protocol field wiring or switching relay racks, the 100-ohm balanced differential pair construction rejects external electromagnetic and radio-frequency noise. This suppression preserves signal integrity for continuous high-speed digital communications without data frame dropouts.

Frequently Asked Questions

Q: What distinguishes part number 51506993-730 within the FS-CCI-HSE-30 series?

A: Part number 51506993-730 designates the specific revision assembly for the 30 m High-Speed Ethernet cable configured for direct connection to Honeywell Safety Manager hardware modules.

Q: What is the minimum allowable bend radius during cabinet installation?

A: The physical installation must maintain a minimum bend radius of at least 5 times the outer cable diameter to avoid damaging internal conductors or shield integrity.

Field Installation Guidelines

  1. Inspect the RJ45 connectors and outer sheath for physical damage prior to pull-through installation.
  2. Maintain a minimum bend radius of at least 5 times the outer cable diameter during routing to prevent internal conductor deformation.
  3. Verify that connector locking tabs click firmly into place on the industrial switch or module port.
  4. Route the cable assembly through separated communication ducts away from high-voltage AC conductors to minimize electromagnetic noise coupling.
  5. Secure the cable with strain-relief ties near terminal points to avoid tension on the RJ45 connector housings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more
Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Selecting the correct control platform represents a foundational engineering decision in factory automation. System designers must carefully balance technical parameters against long-term operational requirements when implementing a Programmable Logic Controller (PLC). This article examines the critical evaluation metrics, physical scale classifications, and operational architectures of modern control systems.

Read more