Skip to content

What are you looking for?


You may also like

FC-TSAL-1620M Honeywell Analog Input ModuleFC-TSAL-1620M Honeywell Analog Input ModuleFC-TSAL-1620M Honeywell Analog Input Module
FC-TSAL-1620M Honeywell Analog Input Module
FC-TSAL-1620M Honeywell Analog Input Module
FC-TSAL-1620M Honeywell Analog Input Module

FC-TSAL-1620M Honeywell Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : FC-TSAL-1620M

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for multi-channel analog signal acquisition in Honeywell Experion PKS platforms, the Honeywell FC-TSAL-1620M (FC-TSAL-1620M Analog Input Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model FC-TSAL-1620M
Brand Honeywell
Origin USA
Weight 0.95 lbs (0.43 kg)
Dimensions 210 x 70 x 60 mm / 137 x 40 x 147 mm
Operating Temp -40 to +70 deg C
Power Consumption Internal processing voltage 0-4 VDC
Input Channels 16 analog input channels
Supported Input Types 4-20 mA, 0-5 V, thermocouples
Signal Range 0-22 mA / 0-5.5 V
Resolution & Accuracy 16-bit, +/-0.1% of full scale
Input Resistance >= 100 kOhm
Fuse Rating 315 mA

Channel-to-Channel Isolation & Signal Integrity

The FC-TSAL-1620M incorporates complete channel-to-channel and channel-to-earth galvanic isolation across all 16 input paths to guarantee high noise rejection. Designed for integration with 4-20 mA HART loop protocol transmitters and voltage signals, the conditioning circuitry preserves high 16-bit resolution accuracy under dynamic industrial noise. The module includes active line diagnosis limits (4-22 mA / 1-5.5 V) that continuously monitor loop integrity, ensuring open-circuit and short-circuit field conditions are detected without disturbing adjacent analog channels.

Frequently Asked Questions

Q: What protection measures prevent high-voltage transients on field loops from damaging the FC-TSAL-1620M backplane circuit?

A: Each channel features individual channel-to-channel and channel-to-earth galvanic isolation, paired with onboard 315 mA fuses to isolate overcurrent conditions locally.

Q: How does the module handle extended input signal levels beyond standard 4-20 mA or 0-5 V limits?

A: The analog input conversion hardware supports an over-range measurement span of 0-22 mA and 0-5.5 V, allowing accurate signal evaluation up to full scale limits.

Field Installation Guidelines

  1. Power down the system chassis or field loop supply prior to inserting the module onto the DIN rail, chassis, or backplane connector.
  2. Route thermocouple and 4-20 mA instrument field cables in dedicated, shielded raceways isolated from high-voltage AC lines.
  3. Verify that all shield drain wires are terminated to a single earth ground point to preserve channel-to-earth isolation performance.
  4. Ensure environmental operating conditions stay within -40 to +70 deg C and relative humidity does not exceed 95% RH (non-condensing).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more