Only 10 left - Selling fast

PRODUCT SKU : FC-SАO-0220М

PRODUCT TYPE : Safe Analog Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell FC-SAO-0220M Safe Analog Output Module is engineered for precise analog control in safety-critical automation systems. It provides two galvanically isolated output channels, each supporting 0–20 mA or 4–20 mA signals. With integrated diagnostics, watchdog functionality, and independent de-energizing capability, the module ensures reliable performance and compliance with international safety standards.

Key Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: FC-SAO-0220M

  • Product Type: Safe Analog Output Module

  • Output Channels: 2 channels, galvanically isolated

  • Output Type: 0–20 mA or 4–20 mA (active or passive)

  • Converter Resolution: 12-bit D/A and A/D per channel

  • Load Requirements: Supports resistive or capacitive loads (inductive loads not supported)

  • Diagnostics: Output accuracy tests, de-energization capability, cross-talk monitoring

  • Secondary De-Energizing: Watchdog and processor can independently disable outputs

  • Power Requirements:

    • 5 VDC: 30 mA

    • 24 VDC: 65 mA + 30 mA per active output

  • Loop Powering: Max loop resistance 600 Ω, max output voltage 30 VDC

  • External Powering: Max 40 VDC, minimum voltage drop <7.5 V

  • Off Current: <0.05 mA

  • WDG Input Current: 0.5 mA

  • Space Requirements: 4 TE, 3 HE (equivalent to 4 HP, 3U)

  • Coding: Module code holes A9, C5; chassis code large pins A9, C5

Features

  • High Precision: 12-bit converters for accurate analog control.

  • Safety-Oriented Design: Independent watchdog and processor de-energizing.

  • Robust Diagnostics: Continuous monitoring of output accuracy and stability.

  • Flexible Output Options: Supports both active and passive current loop configurations.

Application Scenarios

  • Process Safety Systems: Controls actuators and analog devices in chemical plants.

  • Emergency Shutdown Systems: Provides reliable analog outputs for ESD logic.

  • Power Generation: Used in turbine and boiler safety systems.

  • Industrial Automation: Suitable for manufacturing environments requiring precise analog control.

FAQ

Q: How many output channels does the FC-SAO-0220M provide?  A: It supports 2 galvanically isolated analog output channels.

Q: What signal ranges are supported?  A: Both 0–20 mA and 4–20 mA signals.

Q: Can the module drive inductive loads?  A: No, it supports only resistive or capacitive loads.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more