Skip to content

What are you looking for?


You may also like

F60 AI 801 | HIMA HIMatrix 8-Channel Analog Input ModuleF60 AI 801 | HIMA HIMatrix 8-Channel Analog Input ModuleF60 AI 801 | HIMA HIMatrix 8-Channel Analog Input Module
F60 AI 801 | HIMA HIMatrix 8-Channel Analog Input Module
F60 AI 801 | HIMA HIMatrix 8-Channel Analog Input Module
F60 AI 801 | HIMA HIMatrix 8-Channel Analog Input Module

F60 AI 801 | HIMA HIMatrix 8-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : F60AI801

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The HIMA F60 AI 801 (984600801) is a high-integrity analog input solution designed for the HIMatrix F60 safety-related controller series. Engineered for SIL 3 applications, this module provides the precision and diagnostic coverage required for mission-critical monitoring in hazardous environments. It serves as a robust interface between field sensors and the central safety logic, ensuring fail-safe data transmission via SafeEthernet.

Core Technical Specifications

  • Input Architecture: 8 independent, high-precision analog channels.

  • Signal Support: Fully configurable for 0/4-20 mA current loops or 0-10 V voltage inputs.

  • Data Resolution: 16-bit processing for high-fidelity signal acquisition.

  • Measurement Precision: ±0.1% of full-scale value at 25°C, ensuring minimal signal drift.

  • Connectivity Protocols: Supports SafeEthernet for safety-critical loops and Modbus TCP for integration with standard SCADA/HMI systems.

  • Fault Detection: Comprehensive internal diagnostics for open-circuit detection, short-circuits, and signal out-of-range monitoring.

Operating Parameters

  • Nominal Supply Voltage: 24 VDC (Functional range: 18 V to 30 V).

  • Current Consumption: Approximately 200 mA at 24 V (Maximum power draw: 5 W).

  • Temperature Tolerance: Designed for industrial operating environments from 0°C to +60°C.

  • Isolation: Galvanic isolation between the input channels and the internal system bus.

Application Scenarios

The F60 AI 801 is typically deployed where sensor failure could lead to catastrophic events. Common applications include:

  • Pressure Monitoring: High-pressure trip systems in chemical processing.

  • Level Control: Overfill protection systems for fuel storage tanks.

  • Gas Detection: Integration with safety-rated toxic or flammable gas sensors.

Frequently Asked Questions

Q: Does the F60 AI 801 require specific software for configuration?A: Yes, the module is configured using the HIMA SILworX engineering tool, which allows for individual channel parameterization and safety logic mapping.

Q: Can I use this module for non-safety-related measurements?A: While designed for SIL 3 safety functions, it can certainly process standard industrial signals, providing the added benefit of high-end diagnostic feedback for non-critical processes.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more