Skip to content

What are you looking for?


You may also like

CHBX01R 2VAA008575R1 Compact Bus Extender | ABBCHBX01R 2VAA008575R1 Compact Bus Extender | ABBCHBX01R 2VAA008575R1 Compact Bus Extender | ABB
CHBX01R 2VAA008575R1 Compact Bus Extender | ABB
CHBX01R 2VAA008575R1 Compact Bus Extender | ABB
CHBX01R 2VAA008575R1 Compact Bus Extender | ABB

CHBX01R 2VAA008575R1 Compact Bus Extender | ABB


Only 10 left - Selling fast

PRODUCT SKU : CHBX01R 2VAA008575R1

PRODUCT TYPE : Control System Accessories

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed bus extension in horizontal row topologies, the ABB CHBX01R 2VAA008575R1 (CHBX01R Compact Bus Extender) provides direct physical/electrical execution for interconnecting host logic blocks.

Hardware Specifications

Parameter Specification
Model CHBX01R (Product ID: 2VAA008575R1)
Brand ABB
Origin Sweden / Switzerland
Weight 0.082 kg
Dimensions 30 mm x 127 mm x 31 mm
Operating Temp 0 to +60 deg C (Standard industrial parameters)
Power Consumption Dependent on passive backplane load termination metrics
Product Type Control System Accessory
Customs Tariff Number 85371091
Bus Compatibility HN800 devices row (RIGHT side connection)
WEEE Category 5. Small Equipment (No external dimension more than 50 cm)
Battery Count 0

Profinet / EtherNet/IP Deterministic Networks and Bus Bridging

The physical design of the hardware sub-assembly interfaces directly with the right-hand terminal interface of the HN800 device series. It preserves high backplane bus communication velocity across segmented racks without introducing data skew or signal attenuation. This extension routing mechanism ensures that downstream modules maintain absolute firmware flash compatibility with the central processor, supporting seamless communication cycles over Profinet / EtherNet/IP deterministic networks while keeping propagation latencies within nominal microsecond tolerances.

Frequently Asked Questions

Q: Does the bus extender support live hot-swap insertion on an active HN800 backplane rack?

A: No. To prevent signal line glitches, impedance mismatches, or power drops along the extended backplane bus segment, the HN800 rack assembly must be powered down before executing mechanical connection.

Q: How does this module affect the I/O density scaling of the primary control node?

A: The CHBX01R functions as a physical and electrical bridge to allow horizontal row expansion. It does not possess independent registers and does not reduce or restrict the master controller's capacity for I/O density scaling.

Q: What are the grounding requirements for the extended backplane bus row?

A: The chassis ground is established through the primary rail mounting hooks. The extended device row must share a common ground reference with the host HN800 master rack to suppress common-mode electrical noise.

Field Installation Guidelines

  • Orientation and Position: Install the module exclusively on the far right end of the HN800 device row. Ensure the interlocking bus contacts are fully aligned horizontally before execution.

  • DIN Rail Fastening: Snap the unit securely onto a standard grounded 35 mm DIN rail. Verify that the mechanical locking clip locks into position to counter continuous industrial vibration.

  • Cable Routing Restrictions: Keep external communication links and low-voltage field loop cabling isolated from heavy power generation lines to prevent induced electromagnetic noise on the extended parallel bus traces.

  • Thermal and Physical Clearances: Observe the standard vertical clearance boundaries above and below the 127 mm height profile to facilitate proper convective heat dissipation through the module row.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more