Skip to content

What are you looking for?


You may also like

BMEH582040 | Schneider Electric | Modicon M580 Redundant Processor ModuleBMEH582040 | Schneider Electric | Modicon M580 Redundant Processor ModuleBMEH582040 | Schneider Electric | Modicon M580 Redundant Processor Module
BMEH582040 | Schneider Electric | Modicon M580 Redundant Processor Module
BMEH582040 | Schneider Electric | Modicon M580 Redundant Processor Module
BMEH582040 | Schneider Electric | Modicon M580 Redundant Processor Module

BMEH582040 | Schneider Electric | Modicon M580 Redundant Processor Module


Only 10 left - Selling fast

PRODUCT SKU : BMEH582040

PRODUCT TYPE : Processor Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider Electric BMEH582040 serves as the core intelligence for high-availability Modicon M580 Hot Standby (HSBY) architectures. This redundant processor module ensures continuous process operation by providing instantaneous failover between primary and standby units. It handles complex automation tasks including motion control, SSI encoder interfacing, and HART communication within a native Ethernet backplane environment. We supply this processor as 100% brand new, original equipment, offering a cybersecure and high-performance foundation for critical infrastructure and 24/7 industrial production.

Technical Specifications

The BMEH582040 utilizes advanced memory management and high-speed execution to maintain deterministic control over large-scale distributed networks.

  • Processor Type: Redundant (Hot Standby)

  • Program Memory: 8 MB (Integrated RAM)

  • Data Storage: 768 kB (Data RAM) + 4 GB (Expandable Flash)

  • Execution Speed: 40 Kinst/ms (100% Boolean) / 30 Kinst/ms (65% Boolean + 35% fixed arithmetic)

  • Integrated Connectivity: 1 Ethernet Service Port, 2 Ethernet Device Network Ports, 1 Ethernet HSBY Port, 1 USB Type Mini B

  • Network Capacity: Supports 8 remote I/O stations and 64 distributed equipment devices

  • Cybersecurity Standards: Achilles Level 2 certified

  • MTBF Reliability: 650,000 Hours

  • Current Consumption: 270 mA at 24 V DC

  • Operating Temperature: 32 to 140 °F (0 to 60 °C)

  • Weight: 1.872 lb (0.849 kg)

Engineering Advantages

  • Seamless Redundancy (HSBY): The dedicated Ethernet HSBY port synchronizes data between primary and standby processors in real-time. If the primary unit fails, the standby processor assumes control without bumping the process, preventing costly unscheduled downtime.

  • Defense-in-Depth Cybersecurity: This processor incorporates robust security features including an embedded firewall, IPSec communication, and firmware signatures. Achilles certification confirms the unit's resistance to Denial of Service (DoS) attacks, protecting your plant floor from evolving cyber threats.

  • Integrated Network Management: The module manages up to 64 distributed devices and 8 RIO stations directly. It supports RIO and DIO scanners simultaneously, allowing engineers to mix remote I/O and smart devices like drives and flow meters on a single Ethernet network.

  • High-Speed Logic Execution: With performance reaching 40,000 instructions per millisecond, the BMEH582040 solves complex logic and arithmetic tasks almost instantaneously. This speed is essential for high-speed bottling, packaging, and turbine control applications.

  • Comprehensive Visual Diagnostics: A massive array of 15 status LEDs provides immediate feedback. Technicians can identify which processor is Primary (PRIM) or Standby (STBY), monitor the Hot Standby link status (Hsby Diag), and detect memory or I/O faults without connecting a PC.

FAQs

  • What is required for a functional Hot Standby system?

    You must use two identical BMEH582040 processors in a dual-rack configuration connected via a fiber optic or copper HSBY sync cable. Both processors must run the same firmware version to ensure successful data synchronization.

  • Can the BMEH582040 handle motion control and HART data?

    Yes. The processor natively supports SSI encoder interfaces and HART pass-through. This allows you to calibrate smart field instruments and manage multi-axis motion tasks directly through the M580 platform.

  • Is this module compatible with X80 I/O?

    The BMEH582040 fully supports the Modicon X80 I/O range. It manages both local racks and remote drops, providing a scalable migration path for users upgrading from older Quantum or Premium systems.

  • In what condition is this hardware sold?

    We guarantee this BMEH582040 is 100% Brand New original Schneider Electric stock. It arrives in factory-sealed packaging with a valid GTIN (3606485439976) and full manufacturer documentation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more