The Bently Nevada 80917-01, also cataloged as the 80917 Signal Conditioner, operates as a dedicated hardware component for phase reference signal processing and excitation power distribution within machinery monitoring networks.

Hardware Specifications

Parameter Specification
Model 80917-01
Brand Bently Nevada
Origin USA
Weight 0.9 kg
Dimensions 229 mm x 102 mm x 51 mm
Operating Temp -20 deg C to +55 deg C
Power Consumption Powered via internal regulated transducer excitation supply
Input Channels 2 fully independent Keyphasor input channels
Supported Transducers Optical Keyphasor pickups, Proximitor-based Keyphasor probes
Signal Output Conditioned logic-level and analog phase reference outputs
Form Factor Portable bench-top or field instrument

Gap Voltage Validation and Rotor Dynamics Analysis

The 80917-01 conditions raw pulse signals from proximity probes and optical pickups into stable, square-wave once-per-turn timing pulses essential for rotor dynamics tracking. When interfacing proximity probes, establishing proper mechanical bias through gap voltage validation against the nominal -10 VDC baseline ensures clean trigger edge detection across varying machine speeds. Internal signal filtering prevents cross-talk suppression failures, providing noise-free phase reference markers for precise 1X vibration vector phase angle calculation and dynamic balancing.

Frequently Asked Questions

Q: What transducer types are compatible with the dual input channels of the 80917-01?

A: The input channels support optical Keyphasor pickups as well as standard Proximitor-based eddy-current proximity probes.

Q: How does the unit power connected Keyphasor transducers?

A: The instrument contains an integrated regulated excitation power supply that provides stable transducer excitation directly to connected probes.

Field Installation Guidelines

  1. Place the 80917-01 unit securely on a stable bench surface or field enclosure plate near the rotating machinery.
  2. Connect the Keyphasor transducer cable leads to the dedicated BNC or terminal block input channels.
  3. Verify that the DC bias or optical signal alignment provides a clean logic-level pulse transition without double-triggering.
  4. Connect the conditioned logic or analog phase outputs to the analysis instrument or monitoring rack backplane.
  5. Ensure proper shield termination to common earth ground at the signal receiver end to eliminate EMI noise pickup.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more