Product Details

The 3500/33M-01-00 16-Channel Relay Module is a full-height system component designed for the Bently Nevada 3500 Series Machinery Protection System. It provides 16 independent relay outputs to execute voting logic and trip commands based on alarm statuses or measured variables. This specific catalog configuration includes a standard 16-channel relay output module with silver contacts and operates without hazardous area approvals.

Functional Operation and Voting Logic

Each of the 16 relay channels can be programmed independently using Boolean AND and OR logic equations through the 3500 Rack Configuration Software. The alarm drive logic evaluates alert statuses, danger statuses, Not-OK conditions, or individual measured variables from any monitor channel within the rack. Four groups of four channels feature hardware selection switches to configure the relays for either Normally Energized (NE) or Normally De-energized (ND) operation.

Hardware Configuration and Output Modules

The module occupies any available slot to the right of the Transient Data Interface (TDI) Module within the 3500 rack framework. The -01 suffix designates the standard 16-Channel Relay Output Module featuring single-pole double-throw (SPDT) epoxy-sealed relays with standard silver contacts. The -00 suffix indicates that the unit is supplied without specialized hazardous location agency approvals. Front-panel LED indicators display real-time module health, communication activity, and individual channel alarm states.

Parameter Specification
Model 3500/33M-01-00
Brand Bently Nevada
Product Type 16-Channel Relay Module
Number of Channels 16 channels
Relay Type Single-pole double-throw (SPDT)
Power Consumption 5.8 W typical
Operating Temperature -30 degC to +65 degC
Storage Temperature -40 degC to +85 degC
Main Module Dimensions 241 mm x 24.4 mm x 242 mm
Main Module Weight 0.7 kg

Frequently Asked Questions

Q: How can the relay outputs be programmed to respond to rack alarms?

A: Each relay output utilizes programmable AND and OR logic combining alert states, danger states, Not-OK conditions, or individual measured variables across the rack.

Q: What type of relay contacts are included in this -01 configuration?

A: This model utilizes standard single-pole double-throw (SPDT) relays equipped with silver contacts suitable for standard industrial load switches.

Q: Can this module be placed in any slot within the 3500 rack?

A: It can be placed in any available slot located to the right of the Transient Data Interface (TDI) Module.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more