3500/32-01-01 Bently Nevada 4-Channel Relay Module3500/32-01-01 Bently Nevada 4-Channel Relay Module3500/32-01-01 Bently Nevada 4-Channel Relay Module
3500/32-01-01 Bently Nevada 4-Channel Relay Module
3500/32-01-01 Bently Nevada 4-Channel Relay Module
3500/32-01-01 Bently Nevada 4-Channel Relay Module

3500/32-01-01 Bently Nevada 4-Channel Relay Module


Only 10 left - Selling fast

PRODUCT SKU : 3500/32-01-01

PRODUCT TYPE : Relay Modules

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 3500/32-01-01 4-Channel Relay Module is an output component designed for the Bently Nevada 3500 Series Machinery Protection System. It provides four independent relay channels to actuate external alarm or shutdown mechanisms based on programmed voting logic from monitor modules. This specific catalog configuration includes a 4-channel relay I/O module and carries CSA, NRTL, and C agency approvals for hazardous locations.

Relay Logic and Alarm Control

The module receives alarm and status data from other modules across the rack backplane to execute user-defined voting logic. Operators configure each relay channel via the 3500 Rack Configuration Software to respond to specific Alert or Danger conditions. This ensures reliable automated intervention for critical machinery protection when monitored parameters exceed established safety limits.

Hardware Configuration and I/O Interface

Occupying two front slots in a standard 3500 rack framework, the assembly pairs the main relay processor board with a rear-mounted I/O module. The first -01 suffix designates the 4-channel relay I/O module layout, which accommodates external field wiring connections. The second -01 suffix indicates North American CSA, NRTL, and C certifications for Class I, Division 2 hazardous environments.

Parameter Specification
Model 3500/32-01-01
Brand Bently Nevada
Product Type 4-Channel Relay Module
Number of Channels 4 channels
I/O Module Type 4-Channel Relay I/O [-01]
Agency Approval CSA / NRTL / C (Class I, Division 2) [-01]
Slot Occupancy 2 rack slots
Operating Temperature -30 degC to +65 degC
Storage Temperature -40 degC to +85 degC

Frequently Asked Questions

Q: What is the primary function of the 3500/32-01-01 module?

A: It provides four relay channels to execute alarm or shutdown actions based on programmed voting logic from rack monitor modules.

Q: How are the relay output conditions configured?

A: Relay voting logic and setpoints are programmed directly using the 3500 Rack Configuration Software.

Q: Does this model include hazardous location certifications?

A: Yes, the -01 agency approval suffix designates CSA, NRTL, and C certifications for Class I, Division 2 locations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more