Skip to content

What are you looking for?


You may also like

Bently Nevada 330104-00-25-05-02-00 3300 XL 8 mm Proximity ProbeBently Nevada 330104-00-25-05-02-00 3300 XL 8 mm Proximity ProbeBently Nevada 330104-00-25-05-02-00 3300 XL 8 mm Proximity Probe
Bently Nevada 330104-00-25-05-02-00 3300 XL 8 mm Proximity Probe
Bently Nevada 330104-00-25-05-02-00 3300 XL 8 mm Proximity Probe
Bently Nevada 330104-00-25-05-02-00 3300 XL 8 mm Proximity Probe

Bently Nevada 330104-00-25-05-02-00 3300 XL 8 mm Proximity Probe


Only 10 left - Selling fast

PRODUCT SKU : 330104-00-25-05-02-00

PRODUCT TYPE : Proximity Probes

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 330104-00-25-05-02-00 is an armored 8 mm proximity probe belonging to the 3300 XL transducer platform, designed for precision vibration and shaft position monitoring in fluid-film bearing machinery. This eddy-current transducer delivers reliable non-contact displacement measurements while utilizing an M10 x 1 metric thread profile and integrated stainless steel armor.

Suffix Breakdown & Configuration

The model code establishes a specific mechanical and electrical configuration within the 3300 XL series. The base designation 330104 denotes an 8 mm proximity probe featuring an M10 x 1 metric thread and protective cable armor.

The configuration options specify an unthreaded length of 0 mm (code 00), an overall case length of 250 mm (code 25), and a total cable length of 0.5 metre / 1.6 feet (code 05). It is terminated with a miniature coaxial ClickLoc connector with standard cable construction (code 02) and includes no hazardous-area agency approvals (code 00).

Hardware Specifications

Parameter Specification
Model 330104-00-25-05-02-00
Brand Bently Nevada
Product Type 3300 XL 8 mm Proximity Probe
Thread Size M10 x 1 with armor
Unthreaded Length 0 mm
Overall Case Length 250 mm
Total Cable Length 0.5 metre (1.6 feet)
Connector Type Miniature coaxial ClickLoc connector, standard cable
Agency Approval Not required (Option 00)

Field Installation Guidelines

Do not cut or modify the armored probe cable, as factory termination preserves the precise electrical length required for system calibration. Maintain the manufacturer-specified minimum bend radius of 25.4 mm (1.0 in) to prevent mechanical deformation of the internal coaxial shielding.

Route signal cables away from high-frequency switching conductors to minimize induced electrical noise. Ensure the ClickLoc connector is fully seated and locked before energizing the monitoring system.

Frequently Asked Questions

Q: Does the 330104-00-25-05-02-00 probe include hazardous area certifications?

A: No. Option 00 indicates that agency approvals are not required or included with this specific configuration.

Q: What are the case length and thread specifications for this model?

A: It features an M10 x 1 metric thread profile with protective stainless steel armor, a 0 mm unthreaded length, and a 250 mm overall case length.

Q: Is this probe compatible with standard 3300 XL system components?

A: Yes. It is fully compatible and interchangeable with standard 3300 XL extension cables and Proximitor sensors without requiring bench recalibration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

In industrial automation, precise grounding terminology prevents catastrophic equipment failure. Therefore, engineers must master the foundational concepts of earth and ground. Earth represents the conductive mass of the planet, providing a zero-potential reference point. Ground defines a deliberate or accidental connection between an electrical circuit and earth. Furthermore, an effectively grounded system maintains low impedance to prevent hazardous voltage buildups during electrical faults.

Read more
Essential Guide to Grounding Electronic Equipment in Industrial Automation

Essential Guide to Grounding Electronic Equipment in Industrial Automation

Industrial automation systems require robust grounding for personal safety and fault clearance. Safety grounding minimizes touch potential across exposed metallic enclosures. It ensures rapid clearance of fuses during electrical faults. However, electronic equipment introduces unique performance requirements. Solid-state devices operate at high speeds. Therefore, they exhibit extreme sensitivity to minor voltage transients. Facility engineers must balance electrical safety with operational signal integrity.

Read more
Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

The overall reliability of any industrial automation network relies heavily on its grounding components. Control systems, PLCs, and distributed control systems (DCS) require rigorous earthing to mitigate electrical noise and faults. Engineers must select each component with extreme care. Furthermore, proper interconnection methods dictate whether a facility operates safely or suffers from chronic signal disruption.

Read more