  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 330104-00-05-50-12-00 is a proximity probe from the 3300 XL family for non-contact displacement and vibration sensing on industrial machinery. This configuration specifies a 0 mm unthreaded length (option 00), a 50 mm overall case length (option 05), a 5.0 m (16.4 ft) FluidLoc cable with a miniature coaxial ClickLoc connector (options 50 and 12), while the agency approval field shows a mismatch between 00 in the model number and O5 (CSA, ATEX, IECEx Approvals) in the source text.

Mechanical Dimensions and Cabling

Within the 3300 XL proximity probe configuration, option 00 specifies a 0 mm unthreaded length and option 05 sets a 50 mm overall case length. Verify mounting depth and physical clearance against your equipment layout before installation.

For cabling and termination, option 50 sets a 5.0 m (16.4 ft) total length and option 12 specifies a FluidLoc cable with a miniature coaxial ClickLoc connector. Check cable routing space and connector engagement with the connected transducer or extension cable during maintenance.

Agency Approval Suffix Discrepancy

A conflict appears in the provided source text: the model number ends in 00, whereas the agency approval line lists O5 with CSA, ATEX, and IECEx Approvals. Confirm the exact approval code and site regulatory requirements for 330104-00-05-50-12-00 before ordering or installing this unit.

Technical Specifications

Parameter Specification
Model 330104-00-05-50-12-00
Brand Bently Nevada
Series / Product Type 3300 XL Proximity Probe
Unthreaded Length 0 mm (option 00)
Overall Case Length 50 mm (option 05)
Total Length 5.0 m / 16.4 ft (option 50)
Cable and Connector Miniature coaxial ClickLoc connector, FluidLoc cable (option 12)
Agency Approval (Source Text) O5 (CSA, ATEX, IECEx Approvals) listed in source; verify against model ending 00
Country of Origin Made in U.S.A

Frequently Asked Questions

Q: What case length, cable length, and connector are specified on 330104-00-05-50-12-00?

A: It specifies a 50 mm overall case length (option 05), a 0 mm unthreaded length (option 00), and a 5.0 m (16.4 ft) FluidLoc cable with a miniature coaxial ClickLoc connector (options 50 and 12). Confirm mounting clearance and connector compatibility before installation.

Q: Why does the agency approval setting need verification on this model?

A: The source text lists O5 (CSA, ATEX, IECEx Approvals) on the approval line while the part number ends in 00. Verify the exact agency approval configuration for your site before ordering.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mitigating Static Electricity Hazards in Industrial Automation and Control Systems

Mitigating Static Electricity Hazards in Industrial Automation and Control Systems

Static electricity poses severe fire and explosion risks in facilities handling flammable liquids and powders. During routine factory automation operations, friction from fluid flow, pipeline transport, mechanical mixing, and pneumatic transfer generates electrostatic charges rapidly. Factors like material conductivity, fluid velocity, turbulence, and contact surface area influence charge accumulation rates. Without proper mitigation, these electrostatic charges can discharge as sparks, igniting combustible vapors in the surrounding environment.

Read more
Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

In industrial automation, precise grounding terminology prevents catastrophic equipment failure. Therefore, engineers must master the foundational concepts of earth and ground. Earth represents the conductive mass of the planet, providing a zero-potential reference point. Ground defines a deliberate or accidental connection between an electrical circuit and earth. Furthermore, an effectively grounded system maintains low impedance to prevent hazardous voltage buildups during electrical faults.

Read more
Essential Guide to Grounding Electronic Equipment in Industrial Automation

Essential Guide to Grounding Electronic Equipment in Industrial Automation

Industrial automation systems require robust grounding for personal safety and fault clearance. Safety grounding minimizes touch potential across exposed metallic enclosures. It ensures rapid clearance of fuses during electrical faults. However, electronic equipment introduces unique performance requirements. Solid-state devices operate at high speeds. Therefore, they exhibit extreme sensitivity to minor voltage transients. Facility engineers must balance electrical safety with operational signal integrity.

Read more