Product Details

The 330104-00-16-10-11-00 is an 8 mm proximity probe from the Bently Nevada 3300 XL series, engineered for non-contacting vibration and relative displacement measurement in machinery protection systems. Operating on the eddy current principle, it translates mechanical shaft position variations relative to the probe tip into proportional electrical signals. This specific configuration features a 3/8-24 UNF thread without armor, a 0.0-inch unthreaded length option, a 1.6-inch overall case length, and a 1.0-meter total cable length.

Electrical Performance and Scaling

When paired with a compatible Proximitor Sensor, the probe delivers a scale factor of 7.87 V/mm (200 mV/mil) across a 2.0 mm (80 mils) linear range. Calibration procedures require gap voltage validation targeting a nominal -10 VDC baseline at the electrical center of the linear window, while parallel installations must maintain at least 40 mm of separation to suppress cross-talk.

Mechanical Mounting Guidelines

  • Thread the probe body into the mounting bracket or stator block until the tip touches the target shaft, then back off to establish the initial gap.
  • Monitor the output voltage via a digital multimeter connected to the Proximitor Sensor terminals until it registers -10.0 VDC.
  • Secure the position by tightening the provided hex jam nuts to a maximum torque of 4.5 N m (40 in-lb) to avoid case deformation.
  • Route the 1.0-meter integral cable through conduits or dedicated trays while ensuring electrical isolation from structural ground.
Parameter Specification
Model 330104-00-16-10-11-00
Brand Bently Nevada
Product Type 3300 XL 8 mm Proximity Probe
Thread Scale 3/8-24 UNF-2A (Without armor)
Unthreaded Length Option -00 (0.0 inches)
Overall Case Length Option -16 (1.6 inches)
Total Length Option -10 (1.0 meter / 3.3 feet)
Connector Type -11 (Miniature coaxial ClickLoc connector, fluid-resistant boot)
Agency Approval Option -00 (No hazardous area approvals required)
Probe Diameter 8 mm
Linear Range 2.0 mm (80 mils)
Scale Factor 7.87 V/mm (200 mV/mil)
Operating Temperature -51 deg C to +177 deg C
Weight 0.18 kg
Country of Origin United States

Frequently Asked Questions

Q: What does the 1.6-inch case length option designate for this model?

A: The 1.6-inch case length specifies the physical length of the probe housing from the thread start to the rear connector interface, determining the mounting depth required to clear machine casings.

Q: Does this model include hazardous area agency approvals?

A: No, the final suffix -00 indicates that no CSA, ATEX, or IECEx hazardous area approvals are included.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

In industrial automation, precise grounding terminology prevents catastrophic equipment failure. Therefore, engineers must master the foundational concepts of earth and ground. Earth represents the conductive mass of the planet, providing a zero-potential reference point. Ground defines a deliberate or accidental connection between an electrical circuit and earth. Furthermore, an effectively grounded system maintains low impedance to prevent hazardous voltage buildups during electrical faults.

Read more
Essential Guide to Grounding Electronic Equipment in Industrial Automation

Essential Guide to Grounding Electronic Equipment in Industrial Automation

Industrial automation systems require robust grounding for personal safety and fault clearance. Safety grounding minimizes touch potential across exposed metallic enclosures. It ensures rapid clearance of fuses during electrical faults. However, electronic equipment introduces unique performance requirements. Solid-state devices operate at high speeds. Therefore, they exhibit extreme sensitivity to minor voltage transients. Facility engineers must balance electrical safety with operational signal integrity.

Read more
Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

The overall reliability of any industrial automation network relies heavily on its grounding components. Control systems, PLCs, and distributed control systems (DCS) require rigorous earthing to mitigate electrical noise and faults. Engineers must select each component with extreme care. Furthermore, proper interconnection methods dictate whether a facility operates safely or suffers from chronic signal disruption.

Read more