PRODUCT SKU : 330103-00-06-05-02-05

PRODUCT TYPE : Proximity Probes

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 330103-00-06-05-02-05 is an 8 mm eddy-current proximity probe from the Bently Nevada 3300 XL series, engineered for precise vibration and position measurements in rotating machinery. This metric-threaded transducer provides an analog voltage output directly proportional to the gap between the probe tip and a conductive target surface, supporting advanced machinery protection and condition monitoring.

Model Configuration and Suffix Breakdown

The ordering number incorporates specific physical, electrical, and environmental configuration codes. The base model 330103 designates the metric 3300 XL 8 mm proximity probe featuring an M10 x 1 thread.

  • 00: Unthreaded length option of 0 mm.
  • 06: Overall case length option of 60 mm.
  • 05: Total cable length option of 0.5 metre (1.6 feet).
  • 02: Miniature coaxial ClickLoc connector with standard cable.
  • 05: Multiple agency approval option including hazardous location certifications.

Hardware Specifications

Parameter Specification
Model 330103-00-06-05-02-05
Brand Bently Nevada
Product Family 3300 XL Proximity Transducer System
Thread Type M10 x 1
Unthreaded Length 0 mm
Case Length 60 mm
Total Cable Length 0.5 m
Connector Type Miniature coaxial ClickLoc
Sensitivity 7.87 V/mm (200 mV/mil)
Agency Approvals Multiple approvals (CSA, ATEX, IECEx)
Weight 0.32 kg
Country of Origin USA

Operating Principles and Integration

This probe operates on eddy-current principles, detecting target distance without physical contact to capture dynamic vibration and static position. It interfaces with a matched Proximitor sensor and extension cable to maintain linear signal transmission. The ClickLoc connector ensures secure, tool-free connection while preventing loosening under severe operational vibration.

Frequently Asked Questions

Q: What thread type is specified for this probe model?

A: The probe utilizes an M10 x 1 metric thread configuration as designated by the 330103 base model.

Q: What is the total length of the integral cable?

A: The cable length option 05 specifies a 0.5-metre (1.6-foot) integral cable equipped with a miniature coaxial ClickLoc connector.

Q: Does this model carry hazardous area approvals?

A: Yes, suffix 05 indicates multiple agency approvals including CSA, ATEX, and IECEx certifications for hazardous environments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Securing Remote Access Tools in Industrial Automation Environments

Securing Remote Access Tools in Industrial Automation Environments

Remote access has evolved from a convenient support option into an indispensable component of modern industrial automation. Consequently, control engineers routinely leverage remote connectivity for PLC programming, DCS diagnostics, and commissioning support to minimize costly plant downtime. However, poorly managed remote access tools—such as shared credentials, always-on sessions, or unsecured cloud relays—create dangerous vulnerabilities in critical control systems. In my 15 years of commissioning industrial automation networks, I have witnessed how inadequate perimeter security exposes factory floors to severe cyber threats. Below, I evaluate the leading remote access solutions and highlight how organizations can secure their operational technology (OT) infrastructure.

Read more
Achieving Deterministic Industrial Networks Through Time-Sensitive Networking (TSN)

Achieving Deterministic Industrial Networks Through Time-Sensitive Networking (TSN)

Industrial automation environments increasingly demand high-speed, deterministic data transmission to coordinate complex machinery and factory automation lines. Therefore, control engineers continually seek networking technologies that eliminate unpredictable latency and packet loss. In my 15 years of commissioning distributed control systems (DCS) and high-speed motion networks, I have witnessed how traditional Ethernet bottlenecks can trigger unforced production stops. Below, I explore how Time-Sensitive Networking (TSN) transforms standard Ethernet into a deterministic communication backbone.

Read more
Comparing PID and Model Predictive Control (MPC) in Industrial Automation

Comparing PID and Model Predictive Control (MPC) in Industrial Automation

Advanced process control strategies remain fundamental for maintaining optimal plant efficiency and product quality. Therefore, control engineers frequently evaluate whether a traditional Proportional-Integral-Derivative (PID) algorithm or a Model Predictive Control (MPC) strategy suits a given application. In my 15 years of commissioning distributed control systems (DCS) and factory automation networks, I have tuned thousands of PID loops while deploying complex MPC packages on multivariable distillation columns. Below, I break down the core operational differences between these two foundational control methodologies.

Read more