Product Details
The 330102-10-45-10-02-05 is an armored 8 mm proximity probe from the 3300 XL series, engineered for vibration, thrust position, and Keyphasor measurements on fluid-film bearing machinery. This eddy-current transducer delivers reliable shaft displacement data while offering enhanced mechanical durability, hazardous-area certifications, and full compliance with API 670 standards.
Suffix Breakdown & Configuration
The model code establishes a specific mechanical and electrical configuration within the 3300 XL platform. The base design features an 8 mm probe with a 3/8-24 UNF thread profile and stainless steel armor.
The configuration options specify an unthreaded length of 1.0 in (code 10) and an overall case length of 4.5 in (code 45). The integrated cable measures 1.0 m (3.3 ft) in length and terminates in a miniature coaxial ClickLoc connector with standard cable construction. It also carries CSA, ATEX, and IECEx hazardous-area agency approvals.
Eddy-Current Operation & Signal Scaling
The probe operates on the eddy-current principle, generating a high-frequency electromagnetic field at the tip to detect gap variations between the sensor and the observed rotating shaft. It delivers a linear measurement range of 2 mm (80 mils) with an output sensitivity of approximately 200 mV/mil.
The stainless steel armor protects the coaxial cable against mechanical stress and environmental exposure. Proper gap voltage validation ensures linearity across the measurement span.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 330102-10-45-10-02-05 |
| Brand | Bently Nevada |
| Product Type | 3300 XL 8 mm Proximity Probe |
| Tip Diameter | 8 mm |
| Thread Size | 3/8-24 UNF |
| Case Length | 4.5 in (114 mm) |
| Cable Length | 1.0 m (3.3 ft) |
| Connector Type | Miniature coaxial ClickLoc, standard cable |
| Agency Approval | CSA, ATEX, IECEx |
| Linear Range | 2 mm (80 mils) |
| Output Sensitivity | ~200 mV/mil |
| Operating Temperature | -52 deg C to +177 deg C (-62 deg F to +350 deg F) |
| Compliance | API 670 mechanical/electrical standards |
| Applications | Vibration, shaft position, Keyphasor measurements |
Field Installation Guidelines
Do not cut or modify the armored probe cable, as factory termination preserves the precise electrical length required for system calibration. Maintain the manufacturer-specified minimum bend radius to prevent alterations to the coaxial geometry.
Route signal cables away from high-frequency switching conductors to minimize induced electrical noise. Ensure the ClickLoc connector is fully seated and locked before energizing the monitoring system, and confirm that installation practices comply with relevant hazardous-area standards.
Frequently Asked Questions
Q: Can the 330102-10-45-10-02-05 probe be hot-swapped during operation?
A: No. Probes must be disconnected only when the monitoring system is de-energized to preserve calibration integrity and prevent electrical transients.
Q: What hazardous area certifications does this probe carry?
A: This model includes CSA, ATEX, and IECEx certifications for safe deployment in classified explosive environments.
Q: How does API 670 compliance benefit users?
A: It guarantees mechanical configuration and electrical stability, ensuring compatibility with industry-standard monitoring systems.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.