Product Details
The 330101-00-59-15-02-05 is an unarmored 8 mm proximity probe belonging to the 3300 XL transducer system, designed for static and dynamic measurements in fluid-film bearing machinery. This eddy-current transducer delivers reliable shaft displacement data while offering hazardous-area certifications and a customized case length for specialized mounting requirements.
Suffix Breakdown & Configuration
The model code defines a specific mechanical and electrical configuration within the 3300 XL platform. The base design features an 8 mm probe with a 3/8-24 UNF thread profile without protective armor (code 330101).
The configuration options specify an unthreaded length of 0.0 inches (code 00) and an overall case length of 5.9 inches (code 59). The integrated cable measures 1.5 metres (4.9 feet) in length (code 15) and terminates in a miniature coaxial ClickLoc connector with standard cable construction (code 02). It also carries CSA, ATEX, and IECEx hazardous-area agency approvals (code 05).
Eddy-Current Operation & Signal Scaling
The probe operates on the eddy-current principle, generating a high-frequency electromagnetic field at the tip to detect gap variations between the sensor and the observed rotating shaft. It delivers a linear measurement range of 2.0 mm (80 mils) with a nominal scale factor of 7.87 V/mm (200 mV/mil).
This response enables simultaneous measurement of static shaft position and dynamic vibration. Proper gap voltage validation ensures linearity across the measurement span.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 330101-00-59-15-02-05 |
| Brand | Bently Nevada |
| Sensor Type | Eddy-current proximity transducer probe |
| Tip Diameter | 8 mm |
| Thread Size | 3/8-24 UNF |
| Linear Range | 2.0 mm (80 mils) |
| Scale Factor | 7.87 V/mm (200 mV/mil) |
| Temperature Range | -52 deg C to +177 deg C (-62 deg F to +350 deg F) |
| Cable Length | 1.5 m (4.9 ft) |
| Approvals | CSA, ATEX, IECEx hazardous area certifications |
Field Installation Guidelines
Inspect the probe case and connector for mechanical integrity before installation. Install the probe tip perpendicular to the shaft surface to ensure accurate displacement measurement and prevent geometric distortion.
Maintain coaxial cable shield integrity by grounding only at the Proximitor end, and avoid routing probe cables near high-voltage conductors to reduce electromagnetic interference. Confirm a nominal gap voltage between -9 VDC and -11 VDC during commissioning for proper calibration.
Frequently Asked Questions
Q: Is this probe suitable for hazardous environments?
A: Yes. Option 05 provides CSA, ATEX, and IECEx certifications for safe deployment in classified explosive environments.
Q: What is the nominal scale factor for this sensor?
A: The probe provides a scale factor of approximately 7.87 V/mm (200 mV/mil), ensuring linear displacement measurement.
Q: Can the probe be used for both static and dynamic measurements?
A: Yes. It measures static shaft position and dynamic vibration simultaneously.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.