PRODUCT SKU : 330101-00-08-05-02-05

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 330101-00-08-05-02-05 is an 8 mm proximity probe from the 3300 XL series with a 3/8-24 UNF thread and no armor. This configuration specifies a 0.0 in unthreaded length (fully threaded case, code 00), a 0.8 in overall case length (code 08), a 0.5 m (1.6 ft) standard cable with a miniature coaxial ClickLoc connector (codes 05 and 02), and CSA, ATEX, and IECEx approvals (code 05).

Mechanical Configuration and Cabling

Base model 330101 defines a 3300 XL 8 mm proximity probe with a 3/8-24 UNF thread and no armor. Code 00 specifies a 0.0 in unthreaded length (fully threaded case) and code 08 specifies a 0.8 in overall case length, so confirm mounting depth and physical clearance against your housing before installation.

For cabling and termination, code 05 sets a 0.5 m (1.6 ft) total cable length and code 02 specifies a standard cable with a miniature coaxial ClickLoc connector. Verify cable routing and connector engagement with the connected transducer or signal path during maintenance.

Hazardous Area Approvals

Code 05 provides multiple agency approvals covering CSA, ATEX, and IECEx for this configuration. Confirm site area classification and approved certification scope against plant requirements before selection or installation.

Technical Specifications

Parameter Specification
Model 330101-00-08-05-02-05
Brand Bently Nevada
Series / Product Type 3300 XL 8 mm Proximity Probe
Thread and Armor 3/8-24 UNF thread, without armor (base 330101)
Unthreaded Length 0.0 in, fully threaded case (code 00)
Overall Case Length 0.8 in (code 08)
Total Cable Length 0.5 m / 1.6 ft (code 05)
Cable and Connector Miniature coaxial ClickLoc connector with standard cable (code 02)
Agency Approvals CSA, ATEX, IECEx (code 05)

Frequently Asked Questions

Q: What mechanical dimensions and cable options are specified on 330101-00-08-05-02-05?

A: It specifies a 3/8-24 UNF thread without armor (base 330101), a 0.0 in unthreaded length / fully threaded case (code 00), a 0.8 in overall case length (code 08), and a 0.5 m (1.6 ft) standard cable with a miniature coaxial ClickLoc connector (codes 05 and 02). Verify mounting clearance and mating hardware compatibility before installation.

Q: Which agency approvals apply to this probe configuration?

A: Code 05 specifies CSA, ATEX, and IECEx approvals. Confirm exact site hazardous-area classification and approval conditions before deployment.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

In industrial automation, precise grounding terminology prevents catastrophic equipment failure. Therefore, engineers must master the foundational concepts of earth and ground. Earth represents the conductive mass of the planet, providing a zero-potential reference point. Ground defines a deliberate or accidental connection between an electrical circuit and earth. Furthermore, an effectively grounded system maintains low impedance to prevent hazardous voltage buildups during electrical faults.

Read more
Essential Guide to Grounding Electronic Equipment in Industrial Automation

Essential Guide to Grounding Electronic Equipment in Industrial Automation

Industrial automation systems require robust grounding for personal safety and fault clearance. Safety grounding minimizes touch potential across exposed metallic enclosures. It ensures rapid clearance of fuses during electrical faults. However, electronic equipment introduces unique performance requirements. Solid-state devices operate at high speeds. Therefore, they exhibit extreme sensitivity to minor voltage transients. Facility engineers must balance electrical safety with operational signal integrity.

Read more
Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

The overall reliability of any industrial automation network relies heavily on its grounding components. Control systems, PLCs, and distributed control systems (DCS) require rigorous earthing to mitigate electrical noise and faults. Engineers must select each component with extreme care. Furthermore, proper interconnection methods dictate whether a facility operates safely or suffers from chronic signal disruption.

Read more