Product Details
The 330101-00-45-15-02-05 is an unarmored 8 mm proximity probe belonging to the 3300 XL series, designed for machinery protection and condition monitoring in turbomachinery applications. This eddy-current transducer provides accurate shaft displacement data for static position and dynamic vibration analysis while offering hazardous-area certifications.
Suffix Breakdown & Configuration
The model code defines a specific mechanical and electrical configuration within the 3300 XL platform. The base design features an 8 mm probe with a 3/8-24 UNF thread profile without protective armor (code 330101).
The configuration options specify an unthreaded length of 0.0 inches (code 00) and an overall case length of 4.5 inches (code 45). The integrated cable measures 1.5 m (4.9 ft) in length (code 15) and terminates in a miniature coaxial ClickLoc connector with a protector and standard cable construction (code 02). It also carries CSA, ATEX, and IECEx hazardous-area agency approvals (code 05).
Eddy-Current Operation & Signal Scaling
The probe operates on the eddy-current principle, generating a high-frequency electromagnetic field at the tip to detect gap variations between the sensor and the observed rotating shaft. It delivers a linear measurement range of 2.0 mm (80 mils) with a nominal scale factor of approximately 200 mV/mil (7.87 V/mm).
This linear voltage output supports radial vibration monitoring, axial thrust position measurements, and Keyphasor or speed reference generation. The 3300 XL series is fully compatible and interchangeable with other system components without requiring bench calibration.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 330101-00-45-15-02-05 |
| Brand | Bently Nevada |
| Sensor Type | Eddy-current proximity transducer probe |
| Tip Diameter | 8 mm |
| Thread Size | 3/8‑24 UNF |
| Linear Range | 2.0 mm (80 mils) |
| Scale Factor | ~200 mV/mil (7.87 V/mm) |
| Temperature Range | -52 deg C to +177 deg C (-62 deg F to +350 deg F) |
| Cable Length | 1.5 m (4.9 ft) |
| Approvals | CSA, ATEX, IECEx hazardous area certifications |
Field Installation Guidelines
Inspect the connector protector and cable integrity before installation. Align the probe tip perpendicular to the shaft surface to ensure accurate displacement readings and prevent geometric distortion.
Maintain coaxial shielding integrity by grounding only at the Proximitor end, and avoid routing probe cables near high-voltage conductors to minimize electromagnetic interference. Confirm a nominal gap voltage between -9 VDC and -11 VDC during commissioning for proper calibration.
Frequently Asked Questions
Q: Can this probe be used in hazardous environments?
A: Yes. Option 05 provides CSA, ATEX, and IECEx certifications for safe deployment in classified explosive environments.
Q: What is the nominal scale factor for this transducer?
A: The probe provides a scale factor of approximately 200 mV/mil (7.87 V/mm) across its linear range.
Q: Is bench calibration required when replacing probes?
A: No. The 3300 XL series is factory-calibrated and interchangeable with other system components without requiring bench recalibration.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.