Only 10 left - Selling fast

PRODUCT SKU : IC200ALG264

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The IC200ALG264 from GE Fanuc is a high-performance VersaMax analog input module engineered for precision current signal measurement in industrial automation systems. It supports 15 independent channels with 15-bit resolution, offering exceptional accuracy and reliability for process monitoring and control.

Designed for seamless integration into the GE VersaMax I/O platform, this module ensures fast response times, robust performance, and easy diagnostics through onboard LED indicators.

Technical Specifications

  • Model: IC200ALG264

  • Series: VersaMax

  • Type: 15-Channel 15-Bit Analog Input Module

  • Input Signal Range: 0–20 mA or 4–20 mA

  • Number of Channels: 15

  • Resolution: 15-bit

    • 4–20 mA: 0.5 µA = 1 count

    • 0–20 mA: 0.625 µA = 1 count

  • Update Rate: 7.5 ms

  • Accuracy (25°C): ±0.3% typical, ±0.5% maximum of full scale

  • Input Impedance:

    • Voltage mode: 100 kΩ (max)

    • Current mode: 200 Ω (max)

  • Input Filter Response: 24 Hz ±20%

  • External Power Supply: Not required (uses internal power)

  • 5V Backplane Current Consumption: 100 mA max

  • 3.3V Backplane Current Consumption: Not applicable

  • LED Indicators:

    • INT PWR — internal field power active

    • OK — backplane power status

  • Dimensions: 110 × 66.8 × 50 mm (4.3 × 2.63 × 1.96 in)

  • Weight: 1.0 kg (approx.)

  • Condition: New & Original in factory packaging

  • Warranty: 12 months

Key Features

  • High-density 15-channel input design for space-efficient installations

  • Excellent measurement accuracy across wide current ranges

  • Fast update rate for real-time signal processing

  • LED indicators simplify diagnostics and maintenance

  • Fully compatible with GE VersaMax PLCs and control systems

  • No external power supply required for operation

Applications

The IC200ALG264 module is ideal for:

  • Process control systems with multiple analog signal inputs

  • Industrial automation requiring precise current measurements

  • Integration with GE VersaMax PLC platforms

  • Monitoring of sensors, actuators, and field devices in manufacturing environments

FAQ

Q: What type of signals does the IC200ALG264 accept?
A: It supports 0–20 mA and 4–20 mA analog current input signals.

Q: Does it require an external power source?
A: No, it uses internally generated power through the backplane.

Q: How many channels are available?
A: The module provides 15 isolated analog input channels.

Q: What is the accuracy of this module?
A: ±0.3% typical and ±0.5% maximum at 25°C of full-scale input.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




  • 5 stars: 5 (100%)
  • 4 stars: 0 (0%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
O
Olivia

We’re very pleased with this analog input module. The performance is excellent, and the module integrates seamlessly with our system. The accuracy is spot on, and the update rate ensures real-time monitoring. Delivery was quick and efficient.

H
Harper

This module is exactly what we needed! It’s easy to install, and the 15 channels are perfect for our control systems. The fast update rate and high accuracy make it an essential part of our setup. Shipping was fast as well.

M
Mia

Great module for industrial automation. The 4–20 mA input range is perfect for our application, and the resolution is accurate. Fast shipping and excellent customer service made this an easy purchase decision. Very happy with the product!

L
Liam

We’ve been using the IC200ALG264 module for a few weeks now, and it has exceeded our expectations. The accuracy is impressive, and the LED indicators make troubleshooting easy. Great product, and the delivery was quick!

N
Noah

This analog input module works perfectly for our automation needs. The 15 channels and high accuracy have been a huge advantage for our process control systems. It integrates easily with the GE VersaMax PLC, and the shipping was prompt. Highly recommend!

Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more