Product Overview

The Allen-Bradley 22-COMM-E is a compact EtherNet/IP adapter designed to integrate seamlessly with PowerFlex 4, 40, and 400 drives. This module enables high-speed industrial Ethernet communication, providing robust network connectivity for distributed control systems. Equipped with a single RJ45 port, it supports multiple TCP connections and high packet rates to ensure efficient data transfer. Its lightweight design and wide operating temperature range make it suitable for diverse industrial environments.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model Number: 22-COMM-E

  • Product Type: EtherNet/IP Adapter

  • Product Line: PowerFlex 40

  • Compatible Drives: PowerFlex 4, 40, 400

  • Communication Port: 1 × RJ45

  • Communication Protocol: EtherNet/IP

  • Data Rates Supported: 10/100 Mbps Full Duplex and Half Duplex

  • Number of TCP Connections: Up to 30

  • RPI: 5 ms minimum

  • Packet Rate: 400 total I/O packets per second (200 in / 200 out)

  • Drive Power Consumption: 350 mA at 5V DC (supplied by host drive or DPI kit)

  • Operating Temperature: -10 to 50 °C (14 to 122 °F)

  • Storage Temperature: -40 to 85 °C (-40 to 185 °F)

  • Relative Humidity: 5–95% non-condensing

  • Status Indicators: 4 LEDs

  • DSI Connector: 20 pins

  • Cabling: RJ-45 CAT compliant cable

  • Weight: 0.13 lbs (0.06 kg)

Application Scenarios

  • Enabling high-speed Ethernet communication for PowerFlex drives

  • Connecting multiple drives within a single EtherNet/IP network

  • Suitable for factory automation, process control, and distributed control systems

  • Ideal for upgrading legacy systems to industrial Ethernet without replacing drives

FAQ

Q: Which PowerFlex drives are compatible with the 22-COMM-E?
A: PowerFlex 4, 40, and 400 series drives.

Q: What is the maximum packet rate supported?
A: Up to 400 I/O packets per second (200 in / 200 out).

Q: Can it operate in harsh environments?
A: Yes, it supports -10 to 50 °C operating temperature and 5–95% non-condensing humidity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more