PRODUCT SKU : 1771-OC

PRODUCT TYPE : Digital DC Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

Allen-Bradley PLC 5 Output Module – Model: 1771-OC  The 1771-OC is a digital DC output module designed for the Allen-Bradley PLC 5 series. It provides eight sourcing outputs with conformal coating for enhanced durability in industrial environments. This module supports medium-voltage DC ranges and is engineered for reliable high-current switching applications.

Technical Specifications

  • Brand: Allen-Bradley

  • Product Line: PLC 5

  • Model: 1771-OC

  • Type: Digital DC Output Module

  • Number of Outputs: 8 sourcing channels

  • Voltage Range: 10–60 VDC

  • DC Operating Voltage: 42–53 VDC

  • Backplane Current Draw: 165 mA

  • Max Continuous Current per Output: 1.5 A

  • Max Continuous Current per Module: 8 A

  • Wiring Arm: 1771-WH

  • Protective Coating: Conformal coat for environmental resistance

  • Data Format: BDC or natural binary

  • Typical AC Signal Delay (Off): 45 ± 15 ms

  • Typical DC Signal Delay (Off): 50 ms

  • Operating Shock Rating: 30 g

  • Weight: 1.25 lbs (0.57 kg)

  • Model Status: Earlier generation module

Application Scenarios

  • Legacy PLC 5 systems requiring DC output modules

  • Machine control applications with medium-voltage DC outputs

  • Industrial automation setups needing conformal-coated modules for durability

  • Replacement in existing PLC 5 racks with 1771-WH wiring arms

FAQ

Q: How many outputs does the 1771-OC provide?  A: It provides eight sourcing DC output channels.

Q: What is the maximum current per output?  A: Each channel supports up to 1.5 A continuous current.

Q: Does the module include protective coating?  A: Yes, it features conformal coating for added environmental protection.

Q: What wiring arm is compatible with this module?  A: The 1771-WH wiring arm is required.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more