Product Overview

The Allen Bradley 1756-CN2RK serves as a high-performance ControlNet communication bridge within the ControlLogix ecosystem. This module facilitates deterministic, high-speed data exchange between controllers and I/O devices across a redundant media topology. We provide this unit as 100% Brand New and Original, featuring factory-applied Conformal Coating to ensure long-term hardware integrity in corrosive or humid industrial atmospheres.

Part Number Breakdown

The 1756-CN2RK alphanumeric code identifies specific technical capabilities:

  • 1756: Identifies the ControlLogix platform compatibility.

  • CN: Designates the ControlNet protocol interface.

  • 2: Indicates the enhanced "High Performance" series with expanded connection capacity.

  • R: Specifies Redundant media support (Dual BNC channels).

  • K: Denotes Conformal Coating for environmental hardening.

Technical Specifications

This module manages complex network traffic with the following engineering parameters:

Feature Specification
Network Protocol ControlNet
Communication Rate 5 Mbps
Channels Dual (Redundant Media Support)
Logix Connections 128 Maximum
Environmental Protection Conformal Coated PCB
Slot Width Single Slot
Weight 0.88 lbs (0.40 kg)
Module Type Communication Bridge / Rack Mount

Engineering Advantages

  • Redundant Data Pathways: Dual BNC ports allow for media redundancy. If a primary cable fails, the module switches to the secondary path instantly, preventing process downtime and maintaining deterministic control.

  • Aggressive Corrosion Resistance: The "K" version conformal coating protects internal circuitry from salt spray, humidity, and chemical contaminants. This makes it essential for wastewater treatment, oil and gas, and chemical processing facilities.

  • Expanded Connection Density: Supporting up to 128 Logix connections, this module handles massive I/O counts and multi-controller interlocking without bottlenecking the backplane.

  • Deterministic Performance: Unlike standard Ethernet, this module utilizes a scheduled Network Update Time (NUT) to guarantee that critical control data arrives precisely when the logic demands it, eliminating network jitter.

FAQs

  • What is the benefit of the "K" suffix on the 1756-CN2RK?

    The "K" signifies a conformal coating. This protective layer shields the electronic components from environmental hazards like moisture and corrosive vapors, significantly extending the module's lifespan in harsh plant conditions.

  • Does this module support redundant controllers?

    Yes. The 1756-CN2RK supports redundant ControlLogix controller architectures. It facilitates the high-speed synchronization required to maintain a seamless transition between primary and secondary processors.

  • Can I replace a 1756-CNB with this module?

    The 1756-CN2RK offers significantly higher performance and connection capacity than the legacy 1756-CNB. However, you must verify your firmware compatibility and RSLogix/Studio 5000 project configuration before upgrading.

  • Is this a factory-sealed unit?

    Absolutely. We only supply 100% Brand New original Allen Bradley hardware. Each 1756-CN2RK arrives in its original factory packaging with a clear chain of custody.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more