Product Description

The Allen Bradley ControlLogix 1756-L62S is a GuardLogix controller module designed for safety and standard control applications. It offers 4 MB of user memory, 478 KB of I/O memory, and supports up to 128,000 digital I/O points. With dual current draw ratings, low power dissipation, and open-style enclosure, the 1756-L62S provides reliable performance in complex automation systems.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: ControlLogix

  • Catalog Number / Model: 1756-L62S

  • Category: PLCs

  • Module Type: GuardLogix Controller

  • Weight: 1.19 lbs (0.54 kg)

  • User Memory: 4 MB

  • I/O Memory: 478 KB

  • Maximum Digital I/O: 128,000

  • Maximum Analog I/O: 4,000

  • Current Draw (5.1 VDC): 1200 mA

  • Current Draw (24 VDC): 14 mA

  • Power Dissipation: 3.5 W

  • Thermal Dissipation: 11.9 BTU/hr

  • Isolation Voltage: 30 V continuous

  • Enclosure Type: Open-style

Application Scenarios

  • Safety-critical automation systems requiring GuardLogix functionality

  • Large-scale industrial control with high I/O capacity

  • Environments needing reliable memory and communication performance

FAQ

Q: How much user memory does the 1756-L62S provide?  A: 4 MB of user memory.

Q: What is the maximum supported I/O capacity?  A: Up to 128,000 digital I/O and 4,000 analog I/O.

Q: What type of enclosure does the module use?  A: Open-style enclosure.

Comparison with Similar Models

  • 1756-L62S: 4 MB user memory, GuardLogix safety controller.

  • 1756-L61: 2 MB user memory, standard ControlLogix controller.

  • 1756-L63: 8 MB user memory, higher performance ControlLogix controller.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more