Skip to content

What are you looking for?


You may also like

Allen-Bradley ControlLogix 1756-IFI6/A Digital Input ModuleAllen-Bradley ControlLogix 1756-IFI6/A Digital Input ModuleAllen-Bradley ControlLogix 1756-IFI6/A Digital Input Module
Allen-Bradley ControlLogix 1756-IFI6/A Digital Input Module
Allen-Bradley ControlLogix 1756-IFI6/A Digital Input Module
Allen-Bradley ControlLogix 1756-IFI6/A Digital Input Module

Allen-Bradley ControlLogix 1756-IFI6/A Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IFI6/A

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IFI6/A is a digital input module for ControlLogix PLC systems, providing 16 channels of high-speed, isolated input monitoring. Designed for robust performance in demanding industrial environments, it ensures accurate signal acquisition and seamless integration with ControlLogix controllers.

Technical Specifications

Module Information

  • Model: 1756-IFI6/A

  • Type: Digital Input PLC Module

  • Input Channels: 16 discrete inputs

  • Input Voltage: 24V DC

  • Input Circuit: Sourcing type with isolation

  • Isolation Voltage: Tested 1500V AC, output to backplane

Performance

  • Maximum Input Current: 10 mA per channel

  • Scan Rate: Suitable for high-speed applications

  • Response Time: Typically <1 ms

  • Bus Current Draw: 200 mA at +5V DC

Environmental Conditions

  • Operating Temperature: 0°C to 60°C

  • Storage Temperature: -40°C to 85°C

  • Relative Humidity: 5–95% non-condensing

  • Vibration Resistance: 2 m/s² acceleration, up to 500 Hz

Physical & Mounting

  • Dimensions (LxWxH): 12.5 cm x 3.5 cm x 11.8 cm

  • Weight: 0.25 kg

  • Mounting: DIN rail or panel mount compatible

Applications

The 1756-IFI6/A module is used for monitoring discrete signals in manufacturing, process control, and automated systems. It integrates with ControlLogix PLCs to provide precise input monitoring for sensors, switches, and other digital devices.

FAQ

Q: How many input channels does the module provide?
A: 16 isolated digital input channels.

Q: What is the input voltage range?
A: Designed for 24V DC discrete signals.

Q: Can this module be mounted on a standard DIN rail?
A: Yes, it supports DIN rail or panel mounting.

Q: Is the module protected against electrical surges?
A: Yes, it features isolation and overvoltage protection per ControlLogix standards.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more