Skip to content

What are you looking for?


You may also like

Allen-Bradley 700DC-P400Z2 Bulletin 700-DC Industrial Control RelayAllen-Bradley 700DC-P400Z2 Bulletin 700-DC Industrial Control RelayAllen-Bradley 700DC-P400Z2 Bulletin 700-DC Industrial Control Relay
Allen-Bradley 700DC-P400Z2 Bulletin 700-DC Industrial Control Relay
Allen-Bradley 700DC-P400Z2 Bulletin 700-DC Industrial Control Relay
Allen-Bradley 700DC-P400Z2 Bulletin 700-DC Industrial Control Relay

Allen-Bradley 700DC-P400Z2 Bulletin 700-DC Industrial Control Relay


Only 10 left - Selling fast

PRODUCT SKU : 700DC-P400Z2

PRODUCT TYPE : Industrial Control Relay

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 700DC-P400Z2 serves as a heavy-duty industrial control relay designed for high-voltage DC control circuits. As part of the Bulletin 700-DC series, this module manages switching logic for motors, solenoids, and large contactors in demanding power environments. While the manufacturer lists this model as discontinued, we provide 100% Brand New, original factory stock to help you maintain legacy control panels without the risks of refurbished hardware.

Technical Specifications

The 700DC-P400Z2 features a robust electromagnetic design tailored for stable operation under high DC thermal loads.

Feature Specification
Contact Configuration 4 N.O. (Normally Open)
Coil Operating Voltage 230V / 250V DC
Actuation Type DC Operated
Mounting Style Standard Rail Mount / Panel Mount
Product Category Industrial Control Relay
Weight 1.78 lbs (0.81 kg)
Construction Heavy-duty bridge-style contacts

Engineering Advantages

  • High-Voltage DC Logic Management: This relay handles 230V-250V DC control signals directly. It eliminates the need for voltage step-down transformers or additional interposing relays when interfacing with high-voltage DC bus systems common in utility and transit applications.

  • Industrial-Grade Arc Suppression: The contact design specifically manages the aggressive arcing characteristics of high-voltage DC. This ensures a significantly longer mechanical and electrical life compared to standard general-purpose relays.

  • Direct Drop-in Maintenance: Since we offer 100% Brand New units, this relay matches the exact footprint and terminal layout of your existing 700DC installations. You avoid the engineering costs associated with re-drilling panels or updating wiring schematics for modern alternatives.

  • Vibration Resistant Rail Mounting: The secure rail-mount mechanism withstands the constant vibration of industrial machinery, preventing intermittent contact signals and ensuring system uptime in harsh manufacturing zones.

FAQs

  • Can I use an AC coil relay as a substitute for the 700DC-P400Z2?

    No. DC-operated relays like the 700DC-P400Z2 utilize a solid core to prevent chattering and overheating. Using an AC relay in a 250VDC circuit will cause immediate coil failure and potential safety hazards.

  • What is the significance of the "400" in the part number?

    The "400" designates the contact arrangement. In this series, it indicates 4 Normally Open (NO) poles and 0 Normally Closed (NC) poles.

  • How do I ensure maximum contact life during installation?

    Always verify that your load does not exceed the rated DC contact current. For inductive DC loads, we recommend installing external surge suppressors to further protect the contacts from back-EMF during disconnection.

  • Is this unit compatible with modern DIN rails?

    Yes, the 700DC-P400Z2 features a versatile mounting base that accommodates standard industrial rails as well as direct-to-panel screw mounting for maximum stability.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more